background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0058#00 

31.03.2017 

 

 

USER MANUAL 

 

 

VALENTINO 1300 F, VALENTINO 1300 LF/FR, 

VALENTINO 1300 LFR 

G20/G25 (Natural Gas) G30/G31 (Propane-Butane/Propane) 

 

   

 

 
 
 
 
 

Produced by: 

Planika Sp. z o.o. 

ul. Bydgoska 38 

86-061 Brzoza 

Poland

 

Содержание MONROE 900 F

Страница 1: ...www planikafires com IG0058 00 31 03 2017 1 USER MANUAL VALENTINO 1300 F VALENTINO 1300 LF FR VALENTINO 1300 LFR G20 G25 Natural Gas G30 G31 Propane Butane Propane Produced by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland ...

Страница 2: ...ween the remote control and the receiver 11 5 3 1 Battery exchange 12 6 USER MENU 13 6 1 Eco Flow 13 6 2 Relay control of additional optional lighting 14 6 3 Fan or damper control 14 6 4 The choice of control options 15 6 5 Date and time settings 15 6 6 Setting the time schedule 16 7 INSTALLATION MENU 17 7 1 Time format of 12 hour or 24 hour 17 7 2 Time schedule 1day 5 2 7 days or manual 18 7 3 Th...

Страница 3: ...emporary change of temperature setpoint 23 8 2 2 Temporary disruption of the time schedule 23 9 SIGNAL QUALITY 24 10 TROUBLESHOOTING 24 11 MAINTENANCE 27 11 1 Cleaning of the glass with anti reflective coating 27 11 2 Assembly of the glass 28 11 3 Dissassembly of the glass 31 12 ENVIRONMENTAL PROTECTION 34 12 1 The device 34 13 WARRANTY 35 14 TECHNICAL SPECIFICATIONS 36 15 CONTACT DETAILS OF THE M...

Страница 4: ... and possible failures that may occur together with their possible causes and way of their solution WARNING The installer must be certified and qualified professional in the field of gas heating and electricity and should have all the required local law permissions CE Declaration of conformity We hereby declare that the design and construction of gas heating device by Planika meet the essential re...

Страница 5: ...he option of choosing the version of the interior of the fireplace and control it by using remote control supplied together with the device through automation system of intelligent buildings or use for this purpose a built in thermostat unit 3 SAFETY WARNING It is obligatory to carefully read the installation and operating instructions before installing and using the fireplace series VALENTINO Thi...

Страница 6: ...items in particular system of ignition and flame failure protection system Do not move the device during its operation The surface of the fireplace series VALENTINO may strongly heat up during use up to more than 100 C WARNING Accessible parts of the devices including the glass can become very hot You absolutely must protect children from contact with the working device Do not operate the machine ...

Страница 7: ... ignition of the device after three restarts and permanent lock of the device activates reset by disconnecting from the power source may be impossible In such cases please contact your distributor or installer In the event of damage or break the glass the device cannot be used and you must close the gas valve and immediately request glass The remote control should be kept out of reach of children ...

Страница 8: ...r Use only regulators that meet the requirements of European Standard EN16129 Use only approved and certified cables connecting gas flexible hose Replace them at least every 2 years Flexible hose supplying gas to the unit should be located away from sharp edges and hot surfaces Avoid bends and twists of flexible connections along the whole length Note that the gas cylinder LPG should be installed ...

Страница 9: ...first startup of the device sediment will appear on the inner surface of the glass glasses turn off the device and allow it to cool to room temperature and then clean the glass see section 11 1 The formation of the RAID is caused by burning volatile components of paints which initially may also have an impact on the image of the flame Fireplace installed in the housing should be fired for the firs...

Страница 10: ...wnika temperaturę w porównaniu z temperaturą w pomieszczeniu w którym zainstalowane jest urządzenie na podstawie odczytów z termometru znajdującego się w pilocie zdalnego sterowania The device is equipped with Wi Fi radio remote control 868 MHz It allows both manual device control as well as control based on schedule or set temperature in a room by the built in remote control thermostat The temper...

Страница 11: ...ries or during your first installation you must establish the communication code between the remote control and the receiver to be able to use the wireless remote control The receiver is in the mounting bracket together with the gas valve and electronic control unit The remote control can communicate with a device only when it is registered on the device To do this you must do the following ...

Страница 12: ...Close the gas valve near the device if the device will not be used for an extended period of time This is the safest remedy Change the position of the receiver to minimize the possibility of receiving unwanted radio signals Follow the specific instructions of the security measures even if the device is not in use 5 3 1 Battery exchange Before using the remote control you must place the two supplie...

Страница 13: ... use all the options and related features available in the user Menu the user can disable it through the appropriate configuration in the installation Menu These features will no longer be visible in the user Menu on the remote control To activate the user Menu you should press and hold button for 2 seconds You can go out of User Menu by pressing button or after waiting five seconds of pressing th...

Страница 14: ...ntrol Built in relay can be used to control the AC Receiver max 230V AC 0 5A This feature can only be turned on and off by using the remote control To activate or deactivate receiver connected to electric relay you must Go to Screen 2 Of the user menu by pressing and holding button for 2 seconds Then again press the buton Enable or disable electric receiver function by pressing the arrow buttons o...

Страница 15: ... features of the time schedule will be available and you will be able to find them on the screen 4 and subsequent in the user Menu To make the choice of how to control a fireplace Go to Screen 4 of the User Menu by pressing and holding the button for 2 seconds Then briefly press three times the button There are three possible control modes of Fireplace control symbolized by two flashing symbols o ...

Страница 16: ...e choices made in the Installation menu available options may include the following time schedule Time schedule with the same settings for each day Time schedule with separate settings for weekdays Monday to Friday and the weekend Time schedule with separate settings for each day For each day you can set two four or six different periods Time schedule can easily set the start time and set temperat...

Страница 17: ...7 INSTALLATION MENU The following options are available in the installation menu Time format of 12 hour or 24 hour Time Schedule 1 day 5 2 7 days The number of periods during each day II IV or VI To activate the Installation menu you should exit the User Menu if it is enabled and then press and hold the button for 10 seconds You can leave Installation Menu after pressing the button or after waitin...

Страница 18: ...ssing the arrow keys on the remote control or o Time schedule with the same settings for each day o Time schedule with separate settings for weekdays Monday to Friday and the weekend o Time schedule with separate settings for each day o Manual Mode 7 3 The periods during the day II IV or VI To change the number of available periods during the day II IV lub VI you should Press and hold the button f...

Страница 19: ...o the configuration of the Relay operating mode and the Fan support you must again press the button 8 CONTROL The remote control has a display and four buttons Thanks to this operation of the device is simple and settings can be easily changed There are two settings Menu available User Manual see chapter 6 Installation Manual see chapter 7 To activate the User Menu press and hold the button for at...

Страница 20: ...creen of the remote control symbols and will start flashing which indicates the fact that the ignition process of the device is taking place and you will also see the hourglass symbol which will not let you manipulate the fireplace In the first place the middle section of the device will be lit on 50 of its power After about one minute solenoid valve gas supply turns on to the side section of the ...

Страница 21: ...e will then turn on and off automatically depending on the manually set temperature and heat demand If the room temperature is approaching the temperature set by the user driver of the device will automatically reduce the height of the flame If the temperature exceeds the temperature set by the user the device driver will automatically turn off the fireplace and start it again if the room temperat...

Страница 22: ...ctions of the furnace can be turned on or off by using a combination of buttons on the remote control Simultaneous pressing buttons and will disable the side sections of the furnace Simultaneous pressing buttons and will enable the side sections of the furnace The middle section of the furnace enters the highest flame mode to ensure proper and immediate firing of the side sections and after a mome...

Страница 23: ...ton or after waiting five seconds from the time you press the last button you return to the main screen where in addition the symbol appears indicating that the set point temperature was adjusted manually Temporary temperature change can be canceled by setting the manually changed value set on the previous value given for the current period In the case of the transition to a new period temporary s...

Страница 24: ...will be indicated by a failure sign and the flashing sign of lack of communication on the remote s screen Most likely the distance between the device and the remote control is too large and the remote should be placed closer to receiver If the error persists despite the change in the distance between the remote and the receiver you must again carry out the process of establishing communication cod...

Страница 25: ...es not make any contact Make sure that the contacts of the communication cable ensure correct contact Damage to the communication cable Replace the communication cable F02 Overheating of the receiver 60 c above room temperature Poor ventilation by the receiver Improve ventilation at the receiver The receiver is in contact with the hot parts Move the receiver so that it does not touch the hot parts...

Страница 26: ...ctrode measure ionization current flow when 0 and 1 8 uA Remove any residue vermiculite or debris from the burner Faulty ionisation electrode measure ionisation current if 0 electrode is damaged Replace the ionisation electrode Triggered shock sensor shake Check the sensor connection Check whether the construction of the fire housing has not been damaged cracked F12 There has been no release of ES...

Страница 27: ... coating WARNING The glass must be removed and cleaned only when it is cooled down to room temperature and the device is turned off To prevent damage to the coating layer on the anti reflective glass is prohibited to use hard sponges steel wool abrasive cleaners and cleaning products containing ammonia Most of the sediments formed on the glass can be removed with a microfiber cloth Other materials...

Страница 28: ...e from persistent dirt and fingerprints Carefully mount the suction cup in the middle of the glass Holding the glass at angle insert its upper edge between the body of the fireplace and the horizontal fixing strip 1 Slide the glass upwards so that its lower edge is above the lower decorative frame D 2 Push lower edge of the glass in the direction of the body of the fireplace so that the surface of...

Страница 29: ...ss in the direction of the body of the fireplace so that the surface of the glass is in vertical position Holding the glass at all times above the decorative frame B move the glass carefully to the left until it stops or to the right depending on the glazing version 3 Move the glass down and carefully set its bottom edge inside the horizontal handle 4 Even out horizontally position of the front gl...

Страница 30: ...s lower edge is placed above the lower decorative frame B 2 Push lower edge of the glass in the direction of the body of the fireplace so that the surface of the glass is in vertical position Move the glass down and carefully set its bottom edge inside the horizontal handle 3 Even out horizontally position of the front glass relative to the side walls so that the side edges of the front glass comp...

Страница 31: ...d the glasses are cooled down to room temperature Carefully mount the suction cup in the middle of the glass Remove the side pressure stripes A by lifting them up and moving them towards the center of the front glass 1 Unscrew the screws B pressing a horizontal strip C by holding the front glass 2 Move the pressure strip to the left and then move down to dismantle it 3 Lift the front glass vertica...

Страница 32: ...ove the pressure strip to the left and then move down to dismantle it Lift the front glass pane vertically to the top so that its bottom edge is above the decorative frame B 2 Holding the glass at all times above the decorative frame B move carefully the glass making sure that its right edge does not hit the decorative frame C 3 Drag the lower part of the front glass to each other so that its lowe...

Страница 33: ...lass Unscrew the screws A pressing a horizontal strip holding the front glass 1 Move the pressure strip to the left and then move down to dismantle it Lift the front glass vertically to the top so that its bottom edge is above the decorative frame B 2 Drag the lower part of the front glass to each other so that its lower edge is beyond the contour of the housing and decorative frame of the device ...

Страница 34: ...he device When the unit reaches the end of its life you should proceed carefully so the parts are suitable for reuse Before removing the device you should do the following Close the gas valve Disconnect the 230 V AC Unscrew the cable connecting the device to the gas valve Remove the device Do not place the product in unsorted waste and take it to an official collection point for this type of waste...

Страница 35: ...the chimney and operating conditions must be in accordance with the user manual The basis for the free repair covered by warranty is a warranty card Warranty Card will expire without a date stamps signatures as well as the amendments made by unauthorized persons Customer entitlement under the guarantee will expire automatically after the warranty period Wszelkie uszkodzenia powstałe w skutek niewł...

Страница 36: ...pensation Yes Circulation hole in the fireplace wall 300 cm2 Type C11 C31 C91 G20 G31 Nominal heat input Hi kW 11 3 9 9 Consumption on max output m3 h 1 20 Consumption on low output m3 h 0 29 Consumption on max output kg h 0 78 Consumption on low output kg h 0 20 Maximum burner pressure mbar 10 5 27 Minimum burner pressure mbar 4 5 9 Nozzle of the main burner mm 1x Ø1 9 1x Ø1 1 Nozzles of the side...