The dimensions and shape of the ventilation grid may be designed according to client specifications
however both the minimum ventilation area of 150 cm2 as well as minimum distance from the edge
of the housing of 110 minimum need to be observed.
•
The dimensions of the housing are to be chosen according to the technical drawings and a ventilation grid or
slot – with ventilation area min 150cm2 – needs to be placed near the base of the unit, minimally 110 mm
below the burner surface.
.
•
If a hood is placed above the burner it needs to be made of non-flammable materials and a minimum distance
of 60 cm from the surface of the burner needs to be observed.
WARNING!!!
If the housing is devoid of a
diagonal hood above the burner one needs to remember that all surfaces inside the housing exposed to
contact with hot air need to be made of non-flammable materials.
•
It is not permitted to use a device which is not housed in some way.