7. Activating the Smoke Detector/Gas Detector/Glass Break Detector.
For each smoke detector/gas detector/glass break detector you use, choose a number from
01 to 08
(notice: must 2
digits)
.
With your system in
programming status,
on your keypad enter the number sequence below. In the place of
In the place of {01 to 08}, enter the number you have chosen for the sensor. After entering the pound sign (#), you
will need to physically trigger the smoking/gas detector/glass break detector to activate them.
A
.
To trigger the smoke detector, depress the clear plastic button on the face of the smoking detector. You will hear a
double beep
sound to indicate that it has been activated.
B. To trigger the gas detector, depress the white plastic button on the face of the gas detector. You will hear a
double
beep
sound to indicate that it has been activated.
C. To trigger the glass break detector, knock your glass window with any metal. Until you hear a
double beep
sound
from your wireless keypad controller to indicate that it has been activated.
Each smoke/ gas detector/glass break detector has to be individually activated using this procedure.
Study
=> {
01
to
08}
=>
#
=>
trigger
Enter the number
selected for this
sensor from 01-08
(Must 2 digits)
Trigger
Smoke detector
Gas detector
Glass break detector
8. Programming multiple functions.
(For first eight zoon only)
First eight zoon can have multiple functions (emergency, home arm)
Emergency function: A sensor programmed to the emergency function will always be operational even when the system is
disarmed, this function is usually programmed for the gas detector, smoking detector, glass break detector.
7
=>
2
=>
*
=>
{01
to
08}
=>2 =>
#
Enter sensor zoon
number between
(01-08)