User’s Manual of GS-4210-16T2S_24T2S_16P2S_24P2S_48T4S
129
This provides a tunneling mechanism to connect remote costumer VLANs through a common MAN space without interfering
with the VLAN tags. All tags use EtherType
0x8100
or
0x88A8
, where 0x8100 is used for customer tags and 0x88A8 are used
for service provider tags.
In cases where a given service VLAN only has two member ports on the switch, the learning can be disabled for the particular
VLAN and can therefore rely on flooding as the forwarding mechanism between the two ports. This way, the MAC table
requirements is reduced.
Edit Interface Setting
The Edit Interface Setting/Status screens in
Figure 4-5-5
&
Figure 4-5-6
appear.
Figure 4-5-5:
Edit Interface Setting Page Screenshot
The page includes the following fields:
Object
Description
•
Port Select
Select port number for this drop down list to set VLAN port setting.
•
Interface VLAN Mode
Set the port in hybrid, access, trunk, tunnel mode.
Hybrid
means the port allows the traffic of multi-VLANs to pass with tag
or untag mode.
Access
indicates the port belongs to one VLAN only.
Trunk
means the port allows traffic of multiple VLAN.
Tunnel
configures IEEE 802.1Q tunneling for a downlink port to another
device within the customer network.
•
PVID
Allow assign PVID for selected port.
The PVID will be inserted into all untagged frames entering the ingress port. The
PVID must as same as the VLAN ID that the port belong to VLAN group, or the
untagged traffic will be dropped.
The range for the PVID is
1-4094.
•
Accepted Type
Determines whether the port accepts all frames or only tagged frames. This
parameter affects VLAN ingress processing. If the port only accepts tagged
frames, untagged frames received on the port are discarded.
Options:
All
Tag Only
Untag Only