background image

Содержание FTP-80X Series

Страница 1: ......

Страница 2: ...100Base FX to 10 100Base TX PoE Media Converter FTP 80x User s Manual...

Страница 3: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Страница 4: ...pment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In...

Страница 5: ...Revision User s manual for PLANET 100Base FX to 10 100Base TX PoE Media Converter Multi mode FTP 802 Single mode FTP 802S15 Rev 1 0 March 2008 Part No 2350 AA3540 000...

Страница 6: ...Pass through LFP 10 6 Installing the Converter 13 7 PoE function 14 8 LED indication 15 9 Cable Connection Parameter 16 10 FTP 80X Technical Specifications 17 APPENDIX A 18 A 1 Device s RJ 45 Pin Assi...

Страница 7: ...ransfer data and power simultaneously The maximum distance between the Injector FTP 80x and PoE PD is 100 meters With FTP 80x installed it is combines the Ethernet digital data with power over the twi...

Страница 8: ...to 15km In the following sections the term FTP 80X indicates the product family above 3 Checklist Your FTP 80X carton should contain the following items 100Base FX to 10 100Base TX PoE Media Converte...

Страница 9: ...4 Product Outlook Overview The layout of FTP 802 is the same as for FTP 802S15 48V DC OFF LFP ON Bottom Rear Panel TOP Panel Front Panel...

Страница 10: ...PoE In Use 10 100Base TX PoE Media Converter 10 100Base TX to 100Base FX LNK ACT Right View One DIP switch for Link Fault Pass Through LFP feature ON to turn on the LLCF and LLR detection And OFF to t...

Страница 11: ...connect the link of transmit Both can immediately alarm administrators the problem of the link media and provide efficient solution to monitor the net Link Loss Carry Forward LLCF FTP 80X incorporates...

Страница 12: ...troubleshooting a remote connection LLR works in conjunction with LLCF When LFP function is enabled the port s transmitter shuts down when its receiver fails to detect a valid receive link LLR should...

Страница 13: ...d link LED unlit no link Media Converter Management Station Switch Hub w SNMP Station Media Converter Management Switch Hub TP TP Broken Fiber LFP ON LFP ON l LED lit established link LED unlit no lin...

Страница 14: ...Cat 5 UTP cable from the 10 100Base TX network to the RJ 45 port on the FTP 80X Connect the 48V DC power adapter to the FTP 80X and verify that the Power LED lights up Turn on the power of the device...

Страница 15: ...s this DC power into the pin of the twisted pair cable pair 1 2 and pair 3 6 If there is very difficult to find a power socket for AC DC Adapter of your non IEEE 802 3af networked device the FTP 80X a...

Страница 16: ...own PoE in Use Green Lit Indicate that the port is providing 48VDC to remote powered device Off Indicate that the port is not providing 48VDC to remote powered device n 100Base FX SC Port LED Color Fu...

Страница 17: ...tion max Twisted Pair Half Full Node to Node Node to Switch Hub 100 meters Multi Mode Converters MM Half Node to Node Node to Switch 412 meters MM Full Node to Node Node to Switch FTP 802 2 kilometers...

Страница 18: ...support Full or half duplex mode by Auto Negotiation TP LED indicators PWR FX LNK ACT TX LNK ACT PoE in Use PoE Power Output 48V DC Max 15 4 watts 350mA Power Pin Assignment 1 2 3 6 End Span Power Sup...

Страница 19: ...t implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 RJ 45 cable pin assignment There are...

Страница 20: ...ment and color as above picture before deploying the cables into your network A 3 Fiber Optical Cable Connection Parameter The wiring details are as below n Fiber Optical patch Cables Standard Fiber T...

Страница 21: ...n regarding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 ESD IEC 6100...

Страница 22: ......

Отзывы: