background image

Trademarks

Copyright © PLANET Technology Corp. 2008.

Contents subject to revision without prior notice.

PLANET  is  a  registered  trademark  of  PLANET  Technology  Corp. 
The  information  in  this  manual  is  subject  to  change  without 
notice. All other trademarks belong to their respective owners.

Disclaimer

PLANET  Technology  does  not  warrant  that  the  hardware  will 
work  properly  in  all  environments  and  applications,  and  makes 
no  warranty  and  representation,  either  implied  or  expressed, 
with  respect  to  the  quality,  performance,  merchantability,  or 

fitness for a particular purpose.

PLANET has made every effort to ensure that this User’s Manual 
is  accurate;  PLANET  disclaims  liability  for  any  inaccuracies  or 
omissions that may have occurred.

Information  in  this  User’s  Manual  is  subject  to  change  without 
notice  and  does  not  represent  a  commitment  on  the  part  of 
PLANET.  PLANET  assumes  no  responsibility  for  any  inaccuracies 
that  may  be  contained  in  this  User’s  Manual.  PLANET  makes  no 
commitment  to  update  or  keep  current  the  information  in  this 
User’s  Manual,  and  reserves  the  right  to  make  improvements 
to  this  User’s  Manual  and/or  to  the  products  described  in  this 
User’s Manual, at any time without notice.

If  you  find  information  in  this  manual  that  is  incorrect, 

misleading,  or  incomplete,  we  would  appreciate  your  comments 
and suggestions.

Содержание FTP-80X Series

Страница 1: ......

Страница 2: ...100Base FX to 10 100Base TX PoE Media Converter FTP 80x User s Manual...

Страница 3: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Страница 4: ...pment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In...

Страница 5: ...Revision User s manual for PLANET 100Base FX to 10 100Base TX PoE Media Converter Multi mode FTP 802 Single mode FTP 802S15 Rev 1 0 March 2008 Part No 2350 AA3540 000...

Страница 6: ...Pass through LFP 10 6 Installing the Converter 13 7 PoE function 14 8 LED indication 15 9 Cable Connection Parameter 16 10 FTP 80X Technical Specifications 17 APPENDIX A 18 A 1 Device s RJ 45 Pin Assi...

Страница 7: ...ransfer data and power simultaneously The maximum distance between the Injector FTP 80x and PoE PD is 100 meters With FTP 80x installed it is combines the Ethernet digital data with power over the twi...

Страница 8: ...to 15km In the following sections the term FTP 80X indicates the product family above 3 Checklist Your FTP 80X carton should contain the following items 100Base FX to 10 100Base TX PoE Media Converte...

Страница 9: ...4 Product Outlook Overview The layout of FTP 802 is the same as for FTP 802S15 48V DC OFF LFP ON Bottom Rear Panel TOP Panel Front Panel...

Страница 10: ...PoE In Use 10 100Base TX PoE Media Converter 10 100Base TX to 100Base FX LNK ACT Right View One DIP switch for Link Fault Pass Through LFP feature ON to turn on the LLCF and LLR detection And OFF to t...

Страница 11: ...connect the link of transmit Both can immediately alarm administrators the problem of the link media and provide efficient solution to monitor the net Link Loss Carry Forward LLCF FTP 80X incorporates...

Страница 12: ...troubleshooting a remote connection LLR works in conjunction with LLCF When LFP function is enabled the port s transmitter shuts down when its receiver fails to detect a valid receive link LLR should...

Страница 13: ...d link LED unlit no link Media Converter Management Station Switch Hub w SNMP Station Media Converter Management Switch Hub TP TP Broken Fiber LFP ON LFP ON l LED lit established link LED unlit no lin...

Страница 14: ...Cat 5 UTP cable from the 10 100Base TX network to the RJ 45 port on the FTP 80X Connect the 48V DC power adapter to the FTP 80X and verify that the Power LED lights up Turn on the power of the device...

Страница 15: ...s this DC power into the pin of the twisted pair cable pair 1 2 and pair 3 6 If there is very difficult to find a power socket for AC DC Adapter of your non IEEE 802 3af networked device the FTP 80X a...

Страница 16: ...own PoE in Use Green Lit Indicate that the port is providing 48VDC to remote powered device Off Indicate that the port is not providing 48VDC to remote powered device n 100Base FX SC Port LED Color Fu...

Страница 17: ...tion max Twisted Pair Half Full Node to Node Node to Switch Hub 100 meters Multi Mode Converters MM Half Node to Node Node to Switch 412 meters MM Full Node to Node Node to Switch FTP 802 2 kilometers...

Страница 18: ...support Full or half duplex mode by Auto Negotiation TP LED indicators PWR FX LNK ACT TX LNK ACT PoE in Use PoE Power Output 48V DC Max 15 4 watts 350mA Power Pin Assignment 1 2 3 6 End Span Power Sup...

Страница 19: ...t implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 RJ 45 cable pin assignment There are...

Страница 20: ...ment and color as above picture before deploying the cables into your network A 3 Fiber Optical Cable Connection Parameter The wiring details are as below n Fiber Optical patch Cables Standard Fiber T...

Страница 21: ...n regarding the EMC the following standards were applied Emission EN 55022 1994 A1 1995 A2 1997 Class A Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024 1998 ESD IEC 6100...

Страница 22: ......

Отзывы: