and s-bend section, as shown in Fig.14.0.
MAINTENANCE ONLY
20. Unscrew the end cap for access to the spring balance adjustment, as shown in Fig. 14.0.
21. Adjust the spring balance: using a 4mm allen key, adjust the screw inside the knuckle. Clock-
wise/Tightening the screw will cause heavier engagement of the spring - this will improve ‘head
droop’. Anticlockwise/loosening the spring balance will fix a ‘rising head’ issue, as shown in Fig.
14.0.
22. Friction adjustment: Clockwise/tightening this screw will apply more friction to the arm mecha-
nisms. The arm will require more force to move, and will not move as far with the momentum of an
individual movement. This should be set to the staff preference, as shown in Fig 14.0.
4.2 WALL MOUNT
STRUCTURAL LOADS - WALL MOUNT:
The structural integrity of the mounting surface is the responsibility of the installer. Structural loads
are as follows:
Fig. 15.0
4.2.1 MARK UP AND MOUNT WALL UNIT
1. Use the wall mount template from the centre page of this document. Measure up 1907mm from
the floor, and align the bottom of the wall mount template with this mark. Position and fix the tem-
plate into position, ensuring that both edges are level to the vertical and horizontal, as shown in Fig.
16.0. Use the template to mark hole positions for cable access and mounting.
2. Installer to select suitable fixings, and fix the wall unit to the structurally sound wall, ensuring that
the unit is level on all edges Fig. 17.0.
3. Reticulate the 240v power to the power supply location, and connect to the fitting at the terminal
block as shown in Fig. 17.0.
Fig. 17.0
Fig. 16.0