Planck VISION SYSTEMS TC160M1 Скачать руководство пользователя страница 9

 

 

 

TC160M1  

 

User Manual

 

(v1.3)

 

www.planckvisionsystems.com 

 

6.1

 

Typical Setups 

 

Notes: The ThermaCheck M1 camera has great flexibility of installation options shown in Section 7. 

 

 

7

 

Mounting Options 

The ThermaCheck M1 camera connects to a standard ¼”-20 thread, used by traditional cameras and mounting 

systems as shown in Figure 12. 

 

Figure 12: Several mounting options for the ThermaCheck M1 Camera 

 

8

 

Why doesn’t ThermaCheck M1 need a blackbody? 

A blackbody is a stable temperature source used in the factory calibration of thermal cameras to make their 

temperature measurements as accurate as possible. Some infrared cameras used for human temperature 

screening require a blackbody source in the background scene to ensure their measurement accuracy. This 

increases both the cost and complexity of the screening solution with minimal added benefit to the user. 

ThermaCheck M1 uses a US manufactured infrared sensor core and advanced factory calibration procedures that 

optimize it for the measurement of human body temperatures. It automatically performs periodic compensation 

Vesa Mounts

 

Rolling Monitor Stand

 

Wall Mount

 

Содержание TC160M1

Страница 1: ...rface Functions 5 5 1 System settings and information 5 5 2 Interactive calibration function 5 5 3 Mask Detection 7 5 4 Screening Capture History 7 5 5 Temperature Threshold Setting 7 6 Temperature Sc...

Страница 2: ...subjects face The M1 Series camera may be used to screen subjects for wearing a mask issuing an alert in the case of noncompliance Recent individual screening results are summarized in a bottom pictur...

Страница 3: ...nector on the camera s rear pig tail 3 Connect power adapter to the wall outlet 4 Connect camera head to a display not provided using the HDMI cable provided 5 Connect provided mouse to camera head th...

Страница 4: ...4 ThermaCheck M1 main display Table 1 Main display features UI Feature Description 1 Cameras Realtime view of visible and thermal cameras 2 Screening Bar Dynamically refreshed recent screening results...

Страница 5: ...the mouse the appropriate display icon The ThermaCheck M1 camera settings are described below 5 1 System settings and information System Tab 1 Selection of the date time field opens a dialog box for...

Страница 6: ...A approved device is preferred If using a blackbody subject set setpoint temperature to 95 97 F 35 36 C and allow the blackbody to reach the setpoint temperature before calibration is started 3 Use th...

Страница 7: ...on choose the date and screening record type Normal High Temp No Mask to perform a search of the screening record as shown in Figure 9 Figure 9 Selecting record type for search of the screening record...

Страница 8: ...rea Figure 11 Adverse environmental conditions for the ThermaCheck M1 camera Notes 1 Temperature measurements of subjects entering the screening area from the outside could be affected if there is a s...

Страница 9: ...le temperature source used in the factory calibration of thermal cameras to make their temperature measurements as accurate as possible Some infrared cameras used for human temperature screening requi...

Страница 10: ...rature is influenced by environmental conditions Individuals with abnormal skin temperature readings should be further evaluated with a medical grade thermometer Planck Vision Systems is not advertisi...

Отзывы: