17
Power-up sequence information from LED
LED A
Action/Sequence
LED B
Action/Sequence
Dark
Initial power-on
Flashing yellow
Initial power-on
Blink yellow
Self test
Solid yellow
Power-on self test
Dark
One (1) second after Flashing green
Self test pass
power-on
LED A status information after initial power-on
LED Status
Description
Solid green
Functional link – normal operation
Flashing yellow
Link working, unrecognized
sync
information
Solid yellow
Receiving DDC information
LED B status information after initial power-on
LED Status
Description
Solid green
Functional system – normal operation
Flashing green
Fault
Solid yellow
DDC power-on, 12V power not detected
Alternating green/yellow
POST failure