Models:
Code
Material
P
max
[bar]
T
max
[°C]
Housing
Rotor
AE
aluminium
st. steel*
55
120
EE
st. steel*
st. steel*
100
120
PE
PVDF
st. steel*
16
60
AR
aluminium
PPS
55
80
ER
st. steel*
PPS
100
80
PR
PVDF
PPS
16
60
* stainless steel: 06 and 08A: 1.4435 (316), 08B: 1.4571 (316)
Technical Data:
Size
Measuring
range [l/min]
Visco-
sity
[mPa s]
Accuracy
[% of m.v.]
Pulses/L
1/8“
0,017...0,83
> 5
± 1,0
ca. 4400
1/8“
0,033...0,83
< 5
± 1,5
ca. 4400
1/4“
0,04...1,6
> 5
± 1,0 (1,5*)
ca. 2170
1/4“
0,09...1,6
< 5
± 1,5 (2,5*)
ca. 2170
1/4“
0,25...8,3
> 5
± 1,0 (1,5*)
ca. 390
1/4“
0,44...8,3
< 5
± 1,5 (2,5*)
ca. 390
*valid for PVDF-version
Repeatability:
0,03 %
Output signal:
2 pulse outputs (reed contact and
Hall sensor)
Protection class:
IP67
Info on viscosity specification:
1 mPa s (as well cPoise) =
1mm ²
/
s
(
cStoke
)
mediumdensity
[
g
/
cm ³
]
Calibration to Increase Accuracy (option):
Cali-
bration
Medium
Viscosity
Accuracy
[%]
S1
ISO VG 2
2,7 mPa s (3,3 mm²/s]
± 1,0
S2
ISO VG 5
6,4 mPa s (7,6 mm²/s]
± 0,8
S3
ISO VG 10
18 mPa s (20,5 mm²/s]
± 0,6
S4
ISO VG 32
75 mPa s (87 mm²/s]
± 0,4
S5
ISO VG 100
290 mPa s (330 mm²/s]
± 0,3
Dimensions:
Size
A [mm]
B [mm]
C [m]
D [mm]
1/8“
52
55
3
32
1/4“
52
55
3
40
Order Code:
Order number: DOZ03.
Oval gear flowmeters
for low flow rates
06. AE. RH. 1. V. 0
Connection / measuring range:
06 = 1/8“ / 1...50 l/h (0,017...0,83 l/min)
(in version EE only)
08A = 1/4“ / 2,4...100 l/h (0,04...1,67 l/min)
08B = 1/4“ / 15...500 l/h (0,25...8,33 l/min)
Material housing / rotor, P
max
, T
max
:
AE = aluminium / stainless steel, 55 bar, 120 °C
EE = st. steel / st. steel, 100 bar, 120 °C
PE = PVDF / stainless steel, 16 bar, 60 °C
AR = aluminium / PPS, 55 bar, 80 °C
ER = stainless steel / PPS, 100 bar, 80 °C
PR = PVDF / PPS, 16 bar, 60 °C
Output signal:
RH = potential-free reed contact and Hall sensor
(2 pulse outputs), 3 m cable
Process connection:
1 = BSP female thread Rp
2 = NPT female thread
Gaskets:
V = FKM
E = EPDM
F = FFKM
Options:
0 = without
HV = for highly viscous media >1000...500.000 mm²/s
(only for 08B)
S = special calibration for higher accuracy
D1 = on-site display with wall bracket
D2 = on-site display with wall bracket,
analogue and pulse output NPN, 3 m cable
9 = please specify in plain text
ATEX version on request
On-Site Display, Transmitter (option D1 and D2):
Display:
6-digit, LCD (different units
possible)
flow rate or total display
Totalizer:
11-digit (not resettable)
6-digit (resettable)
Ambient temperature:
-20 °C ... 80 °C
Supply:
battery, replaceable (CR123A)
Calibration factor:
can be entered and stored
9-point linearization:
medium: water, for other media
please contact PKP.
Protection class:
IP65
Additional only for option D2:
Pulse output:
NPN open collector, scaleable,
adjustable pulse length
Analogue output:
4...20 mA (min / max values
programmable)
Supply:
battery CR123A, additional
5...30 VDC (I ≤ 15 mA)
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S
+49 (0) 6122-7055-0 •
T
+49 (0) 6122 7055-50
[email protected] • www.pkp.de