Electrical Connection / Evaluation units
DOZ03, Code RH
potential free Reed contact and Hall sensor, 3 m cable:
Connection plan:
Hall effect switch:
Rating:
Power Supply: Supply input range:5-24 VDC, 3,5 mA
Output current: 30 mA, max.
Wiring:
Yellow: Hall effect DC+
Brown: Hall effect ground
Green: Hall pulse output
Reed switch:
Rating:
Power rating: 10 W
Switching voltage: 100 V (DC or peak AC)
Switching current: 500 mA (DC or peak AC)
Wiring:
Grey: Reedswitch
White: Reedswitch
Green: Hall effect pulse output
Pulses per liter (PPL)
Meter size
meas. range code
measuring range
pulses/L
1/8“
06
0,017...0,83 l/min
appr.4400
1/4“
08A
0,04...1,67 l/min
appr. 2170
1/4“
08B
0,25...8,33 l/min
appr. 390
Note:
Pulses per liter are shown unit-specifically on the calibration certificate supplied
and on the type plate.
DOZ03 / DOZ05 / DOZ07 Instruction manual 02/2021
page 10