~ 91 ~
5.
Carefully pull out the illuminant connection cable (
H
) until you see the terminal
(
J
) of the cable (see fig. below).
6.
Disconnect the terminal connection.
F
LED
ILLUMINANT
H
I
LLUMINANT CONNECTION CABLE
J
T
ERMINAL OF THE ILLUMINANT CONNECTION CABLE
7.
Replace the used LED illuminant by a new one of the same type and power.
a.
ILCOS D-Code for this illuminant: DSR-1.5/65-S-64
b.
LED module: round lamp.
c.
Max. Wattage: 2*1.50 W.
d.
Round lamp: diameter (Ø) in mm = 64.00.
8.
Replace the other LED illuminant as described above.
9.
To reinstall the LED illuminant(s), please proceed in
reverse order
.
Required minimum distance to surfaces such as pot lids, oven
cloths etc. to avoid any hot parts and risk of fire.
--- m = 0.45 m
Only use self-shielded illuminants to avoid hot parts, risk of fire
and exposure to UV-radiation.