53
6. Network Bridge Function
6.2 Communication set up
6.3 Communication port
1) In the COMMUNICATION TYPE menu, select NETWORK BRIDGE
(WIRELESS or WIRED depending on the type of connection you use) for the
CONTROL
port.
2) Using the SERIAL SETTINGS menu, select the proper baud rate and parity
for the
CONTROL
port, according to the specification of the RS-232 port of
the connected device.
For the NETWORK BRIDGE function, send the data from the computer to the
projector using the
Network Bridge Port
which is configured in
Port Settings
of
web browser. (
&
23
)
3) Using the TRANSMISSION METHOD menu, set up the
CONTROL
port
appropriate for your situation.
• OFF is the default setting of COMMUNICATION TYPE.
• Using the COMMUNICATION menu, set up the communication. Remember
that an inappropriate set up can cause a communication malfunction.
• When one or both of the NETWORK BRIDGE settings is selected in the
COMMUNICATION TYPE menu, the
CONTROL
port cannot receive
RS-232 commands.
• Any number between 1024 and 65535 can be set up as the
Network
Bridge Port
number, except for 41794, 9715, 9716, 9719, 9720, 5900, 5500,
and 4352. 9717 is the default setting.
NOTE
NOTE
Item
Condition
BAUD RATE
4800bps/9600bps/19200bps/38400bps
PARITY
NONE/ODD/EVEN
Data length
8 bit (fixed)
Start bit
1 bit (fixed)
Stop bit
1 bit (fixed)
To set up communication using NETWORK BRIDGE for the projector, use the
COMMUNICATION menu. Open the projector menu and select the OPTION
- SERVICE - COMMUNICATION menu. (
&
OPTION menu
>
SERVICE
>
COMMUNICATION
in the
Operating Guide
)