background image

User manual

 - DRR244 - 7

1.3 

Precautions for safe use

Be sure to observe the following precautions to prevent operation failure, malfunction, or adverse 

affects on the performance and functions of the product. Not doing so may occasionally result in 

unexpected events. Do not handle the Digital Controller in ways that exceed the ratings.

•  The product is designed for indoor use only. Do not use or store the product outdoors or in any of 

the following places.

-  Places directly subject to heat radiated from heating equipment.

-  Places subject to splashing liquid or oil atmosphere.

-  Places subject to direct sunlight.

-  Places subject to dust or corrosive gas (in particular, sulfide gas and ammonia gas).

-  Places subject to intense temperature change.

-  Places subject to icing and condensation.

-  Places subject to vibration and large shocks.

•  Installing two or more controllers in close proximity might lead to increased internal temperature 

and this might shorten the life cycle of electronic components. It is strongly recommended to 

install cooling fans or other air-conditioning devices inside the control cabinet.

•  Always check the terminal names and polarity and be sure to wire properly. Do not wire the 

terminals that are not used.

•  To avoid inductive noise, keep the controller wiring away from power cables that carry high voltages 

or large currents. Also, do not wire power lines together with or parallel to Digital Controller 

wiring. Using shielded cables and using separate conduits or ducts is recommended. Attach a 

surge suppressor or noise filter to peripheral devices that generate noise (in particular motors, 

transformers, solenoids, magnetic coils or other equipment that have an inductance component). 

When a noise filter is used at the power supply, first check the voltage or current, and attach the 

noise filter as close as possible to the Digital Controller. Allow as much space as possible between 

the Digital Controller and devices that generate powerful high frequencies (high-frequency 

welders, high-frequency sewing machines, etc.) or surge.

•  A switch or circuit breaker must be provided close to device. The switch or circuit breaker must be 

within easy reach of the operator, and must be marked as a disconnecting means for the controller.

•  The device must be protected by a fuse 1A (cl. 9.6.2).

•  Wipe off any dirt from the Digital Controller with a soft dry cloth. Never use thinners, benzine, 

alcohol, or any cleaners that contain these or other organic solvents. Deformation or discoloration 

may occur.

•  The number of non-volatile memory write operations is limited. Therefore, use EEprom write mode 

when frequently overwriting data, e.g.: through communications.

1.4 

Environmental policy / WEEE

Do not dispose electric tools together with household waste material.

According to European Directive 2002/96EC on waste electrical and electronic equipment and its 

implementation in accordance with national law, electric tools that have reached the end of their life 

must be collected separately and returned to an environmentally compatible recycling facility.

Содержание DRR244

Страница 1: ...DRR244 Controller Regolatore r gulateur User manual Manuale d uso Manuel utilisateur...

Страница 2: ...conceived for applications related to nuclear power plants weapon systems flight control mass transportation systems Only qualified personnel should be allowed to use device and or service it and only...

Страница 3: ...shielded cables and using separate conduits or ducts is recommended Attach a surge suppressor or noise filter to peripheral devices that generate noise in particular motors transformers solenoids mag...

Страница 4: ...0 60 mV Pot Input 1 150 K CT 50 mA Tolerance 25 C 0 2 1 digit on F s for thermocou ple thermoresistance and V mA Cold junction accuracy 0 1 C C Impedence 0 10 V Ri 110 K 0 20 mA Ri 5 0 40 mV Ri 1 M R...

Страница 5: ...3 DRR244 FNC SET C1 C2 A1 A2 A3 TUN MAN REM 5 Electrical wirings This controller has been designed and manufactured in conformity to Low Voltage Directive 2006 95 EC 2014 35 EU LVD and EMC Directive 2...

Страница 6: ...at one side only AI1 PT NI100 Shield Schermo Rosso Red Bianco White Rosso Red 13 14 15 For thermoresistances PT100 Ni100 For the three wire connection use wires with the same section For the two wire...

Страница 7: ...ons 5 1 f Digital output 0V DO1 PNP DO2 PNP 9 10 19 Digital output PNP including SSR for command or alarm Range 12 VDC 25 mA or 24 VDC 15mA selectable by parameter 282 v out 5 1 g Analogue output AO1...

Страница 8: ...ameter value being inserted 6 1 Meaning of Status Lights Led 3 C1 ON when the command output 1 is active In versions with single analog input it is ON when the valve is opening In the versions with tw...