PL721 User’s Manual
Intra frame period:
Available choices are; 5, 8, 10, 15, 20, 25, 30, 40, 50 & 60
frames per period. This function will let you choose how long
distance between two I-Frames.
Lager value means longer distance between two I-Frames and
this selection is suitable for the stable Network Bandwidth
Environment; so we suggest the smaller value selection is
proper to the worse Network Bandwidth Environment.
Text Overlay:
When enabled, each streamed frame will be overlaid with the
Camera ID (text field) and stamped with date/time (if enabled)
as illustrated below.
Figure 4-12 Text Overlay Setting Example
RTSP Port Access Name
: When RTSP or VLC media-player is used, the port
can be renamed with easy to remember pathname.
For example: the de
Default RTSP Port Access Name is live1.sdp
;
it means your stream name would
be “
RTSP://camera’s IP address/live1.sdp
”
After setups are completed, click
Save
button to implement the settings.