33
UI Element
Description
with the manufacturer.
By default, the interval is set as
8
seconds.
RS232 Parameter
Set the RS232 parameters for the controlled display.
For more information about the parameters, see the
user guide of your display devices.
Parameter
Value
Abbreviation
Baud Rate
9600bps
9600
Data Bits
8bits
8
Parity
None
n
Stop Bits
1
1
By default, its set as
9600-8n1
.
RS232 standby
command
Enter the RS232 standby command of a controlled
display device. For more information about the
command, see the user guide of your display devices.
If you want to disable this function, you can enter
nothing here.
By default, it’s set as blank.
RS232 wakeup
command
Enter the RS232 wakeup command of a controlled
display device. For more information about the
command, see the user guide of your display devices.
If you want to disable this function, you can enter
nothing here.
By default, it’s set as blank.
RS232 hex string
enable
Enable
: select to use the hex numbers of RS232
standby and wakeup commands to control your
display devices. If this is the case, make sure
standby and wakeup commands are manually
converted to their equivalent hex representations
first and then input in
RS232 standby command
and
RS232 wakeup command
.
For example, RS232 wake up command in hex may be:
50 57 52 20 4F 4E 0D 0A
.
Disable
: select to directly send the original
standby or wakeup commands to control display
devices.
By default, it’s set as
Disable
.
Power On
Click to power on the connected display.
Power Off
Click to power off the connected display.