32
UI Element
Description
zero, the display enters standby mode.
Note:
If the connected display doesn’t support
CEC or isn’t correctly configured with RS232
commands, the word “Standby” appears in the
middle of the Guide Screen.
•
If it’s set to 0 minute, it means this function is
disabled, you cannot set the display to standby
mode.
By default, auto standby is set as
1
minute
.
Apply
Click to perform current settings.
Sink Power Management
UI Element
Description
Sink Power
Management
Set display to enter standby mode or to return to their
normal working state through CEC capability or
RS232 commands.
Sink Power Mode
both
: Enable both CEC and RS232 mode to
manage the sink power.
cec
: Enable CEC to manage the sink power.
rs232
: Enable RS232 to manage the sink power.
By default, it's set as
both
.
Interval between
two consecutive
commands to the
sink (Second)
Specify a time interval between sending two
consecutive commands to the sink (in seconds).
The interval should not be less than 0s.
Note:
If you’re not clear about this function, it’s
suggested that you make no changes here or contact