DECOMISSIONING
Should the pump remain inactive for long periods, proceed as follows
1. Wash internally using products suitable for to the fluid being pumped.
2. Close the fluid intake and delivery valves mounted on the pump.
3. Close the air supply using the three-way valve; this will discharge any residual
pressure.
4. If you want to store the pump in the warehouse, you must respect the following:
5. If the pump was in disuse for a long period of time, circulate clean water through
it for some minutes before restarting it to avoid incrustations.
Discharge any residual fluid from the pump. In case
of dangerous, toxic fluids and/or otherwise noxious
products, wash and treat as suitable:danger of
injuries, damage to health and/or death.
Storage must be in a closed and protected environ-
ment at temperatures ranging from 5 to 45°C, and
a humidity level not above 90%.
WARNING
WARNING
T
DEMOLITION AND DISPOSAL
The Piusi MA and Piusi MP pump does not contain dangerous parts; however, when
they are worn out, they must be disposed of in the following manner.
discharge any residual fluid from the pump. In case
of dangerous, toxic fluids and/or otherwise noxious
products, wash and treat as suitable: danger of
injuries, damage to health and/or death.
WARNING
for disposal please contact specialized disposal
businesses and make sure that no small or large
components are dispersed in the environment
which may cause pollution, accidents or direct and/
or indirect damage.
WARNING
1. Disconnect pneumatic supply from pump.
2. Disassemble and remove the pump from its position.
3. Separate elements according to type (see the pump’s composition codes).