Piusi EX 50 12V Скачать руководство пользователя страница 5

22 

 

 

 

 

 

 

 

             M0217 EN

EN

MACHINE DESCRIPTION

PUMP

SELF-PRIMING, VOLUMETRIC, ROTATING ELECTRIC VANE PUMP, 
EQUIPPED WITH BY-PASS VALVE.

MOTOR

BRUSH  MOTOR  POWERED  BY  CONTINUOUS  CURRENT,  LOW 
VOLTAGE,  WITH  INTERMITTENT  CYCLE,  CLOSED  TYPE,  IP55 
PROTECTION CLASS ACCORDING TO CEI EN 60034-5, FLANGE-
MOUNTED DIRECTLY TO THE PUMP BODY.

ATTENTION

MOTOR EQUIPPED WITH  AUTOMATIC THERMAL 
OVERLOAD PROTECTION. SHOULD THE PROTECTION 
ACTIVATE, TURN OFF THE PUMP AND WAIT FOR IT TO 
COOL DOWN.

 

D1     DEFINITION OF CLASSIFIED ZONES 

FOREWORD

Definition of zones as shown in UNI EN 1127-1 standard

ZONE 0

Place where an explosive atmosphere made up of a mix of air and inflam-
mable substances in the form of gas, vapour or mist is continuously pre-
sent, either for long periods or frequently.
Note: Generally speaking, said conditions, when they occur, involve the in-
side of tanks, pipes and containers, etc.

ZONE 1

Place where it is probable that an explosive atmosphere, made up of a mix 
of air and inflammable substances in the form of gas, vapour or mist, can 
occur occasionally during normal operation. 
Note: Said zone can also include:
- places in the immediate vicinity of zone 0;
- places in the immediate vicinity of supply openings; 
- places in the immediate vicinity of filling and and emptying openings; 
- places in the immediate vicinity of appliances, protection systems and fra-
gile glass and ceramic components, or components made of other similar 
materials; 
- places in the immediate vicinity of inadequately sealed stuffing boxes, e.g., 
on pumps and valves with stuffing box.

ZONE 2

Place where it is improbable that an explosive atmosphere, made up of a 
mix of air and inflammable substances in the form of gas, vapour or mist, 
can occur during normal operation, but which, if it does occurs, only per-
sists for a short time. 
Note: Said zone can include, among others, places surrounding the zones 
0 or 1.

ZONE 20

Place where an explosive atmosphere in the form of a cloud of combustible 
powders in the air is continuously present, either for long periods or fre-
quently. 
Note: Generally speaking, said conditions, when they occur, involve the in-
side of tanks, pipes and containers, etc.

ZONE 21

Place where it is probable that an explosive atmosphere, in the form 
of a cloud of combustible powders in the air, can occur occasionally 
during normal operation. 
Note:  Said  zone  can  include,  for  example,  among  others,  places  in 
the immediate vicinity of powder loading and emptying points and 
places where powder layers form or which, during normal operation, 
could  produce  an  explosive  concentration  of  combustible  powders 
mixed with the air.

ZONE 22

Place where it is improbable that an explosive atmosphere, in the form 
of a cloud of combustible powders in the air, occur during normal ope-
ration but which, if it does occur, only persists for a short time. 
Note: This zone can comprise, among others, places near appliances, 
protections  systems  and  components  containing  powder,  out  of 
which the powder can come out due to leaks with the formation of 
powder deposits (e.g., milling salt, where the powder comes out of the 
mills and deposits).

Содержание EX 50 12V

Страница 1: ...M0217ITEN rev 00 EX 50 12V ...

Страница 2: ...RST AID RULES 24 G GENERAL SAFETY RULES 25 H TECHNICAL DATA 26 H1 PERFORMANCE SPECIFICATIONS 26 I ELECTRICAL DATA 27 L OPERATING CONDITIONS 27 L1 ENVIRONMENTAL CONDITIONS 27 L2 ELECTRICAL POWER SUPPLY 27 L3 DUTY CYCLE 28 L 4 FLUIDS PERMITTED 28 M INSTALLATION 28 M1 POSITIONING CONFIGURATIONS AND ACCESSORIES 29 M2 NOTES ON SUCTION AND DELIVERY LINES 29 N CONNECTIONS 30 N1 ELECTRICAL CONNECTIONS 30 ...

Страница 3: ...20 M0217 EN EN B MACHINE AND MANUFACTURER IDENTIFICATION AVAILABLE MODELS 12Vdc MANUFACTURER PIUSI S p A Via Pacinotti 16 A z i Rangavino 46029 Suzzara Mantova Italy ...

Страница 4: ...rtly completed machinery Description PumpdesignedforthetransferofFUEL Model PUMPWITHANTI EXPLOSIVEHOUSINGPROTECTIONSYTEM Serial No refer to Lot Number shown on CE plate affixed to product Yearofmanufacture refertotheyearofproductionshownontheCEplateaffixedtotheprod uct Is intended to be incorporated in a machine or to be with other machines so as to create a machine to which applies Machine Direct...

Страница 5: ...s placesintheimmediatevicinityofinadequatelysealedstuffingboxes e g on pumps and valves with stuffing box ZONE 2 Place where it is improbable that an explosive atmosphere made up of a mix of air and inflammable substances in the form of gas vapour or mist can occur during normal operation but which if it does occurs only per sists for a short time Note Said zone can include among others places sur...

Страница 6: ...e appliance with fixed guards tampered with or remo ved 3 To use the appliance in places where there is risk of explosion and or fires classified in the following zones 0 20 21 22 4 Tointegrateothersystemsand orequipmentnotconsideredby the manufacturer in the executive project 5 To connect the appliance up to energy sources other than those contemplated by the manufacturer 6 To use the commercial ...

Страница 7: ...OLTAGES TO CONNECT THE PUMPS ATTENTION PUMPCANNOTBEUSEDFORREFUELLINGAIRCRAFTS SUPPLIEDBYAVGAS ATTENTION USETHEPUMP ONLYWITHFLUIDSPERMITTED DONOTUSEWITHFLUIDSNOTPERMITTEDTOAVOID DAMAGINGTHEPUMP THEGUARANTEELAPSESINCASE OFMISUSEOFTHEFLUID DONOTUSETHEPUMPWITHLIQUIDFOODPRODUCTS AND ORWATER BASEDFLUIDS DONOTOPERATETHEPUMPDRYTOAVOIDDAMAGE Before connection make sure that the piping and the suction tank ...

Страница 8: ...TONATIONOF SPARKS ALLPUMPINGSYSTEMMUSTHAVEPROPER GROUNDING INCLUDINGTANKAND ANYACCESSORIES DANGER ENFORCEREGULATIONSFORELECTRICALINSTALLATION ALL WIRING AND ELECTRICAL CONNECTIONS MUST BE PERFORMED BY AUTHORIZED AND SUITABLY TRAINED PERSONNEL Never touch the electric plug or socket with wet hands Do not switch the dispensing system on if the network connection cable or important parts of the appar...

Страница 9: ...atingconditions Fluid PETROL Temperature 20 C Suctionconditions Thepipeandthepumppositionrelative tothefluidlevelissuchthatalowpressureof0 3baris generatedatthenominalflowrate Underdifferentsuctionconditionshigherlowpressure valuescanbecreatedthatreducetheflowratecompared tothesamebackpressurevalues Toobtainthebestperfor mance itisveryimportanttoreducelossofsuctionpressu reasmuchaspossiblebyfollow...

Страница 10: ...e 89 654 EEC on work environments In case of non EU countries refer to directive EN ISO 12100 2 4 8 6 ATTENTION Thetemperaturelimitsshownapplytothepumpcompo nentsandmustberespectedtoavoidpossibledamageor malfunction L2 ELECTRICAL POWER SUPPLY NOTE The pump must be powered by DC line the nominal values of which are indicated on the table in the paragraph I ELECTRI CAL DATA The maximum acceptable va...

Страница 11: ...ENTHEELECTRICALBOXTOENSUREPROTECTION AGAINSTTHERISKOFEXPLOSION THERIGHTCLAMPINGSCREWSCOUPLETHATGRANTSTHIS PROTECTIONIS10Nm PRELIMINARY INSPECTION Verify that all components are present Request any missing parts from the manufacturer IFDL UIBU UIF QVNQ IBT OPU TVòFSFE BOZ EBNBHF EVSJOH USBOTQPSU or storage Carefully clean the suction and delivery inlets and outlets removing any dust or other packag...

Страница 12: ... pump Forthisreason itisalwaysadvisabletoprimethepumpwithoutanautomaticdeliverynozzle verifying the proper wetting of the pump Always install a foot valve to prevent the suction pipe from being emptied and to keep the pump wet at all times In this way the pump will always start up immediately the next times it is used When the system is in operation the pump can operate with back pressures of up t...

Страница 13: ...s closed be foreswitchingonthepowersupply afterhavingcheckedtheintegrityof the seal gaskets that ensure the IP55 protection grade For those screws use a 10 nm clamping couple ATTENTION Allmotorsareequippedwithagroundingterminal Makesurealltheplantisproperlygrounded ATTENTION BE SURE TO USE A CABLE GLAND WITH SUFFICIENT PROTECTION GRADE Exd NOTE IN THE EVENT OF INSTALLATION IN ZONES WHICH ARE NOT C...

Страница 14: ...akesurethatthepipingandlineaccessoriesareingoodcondition NOTE THISPUMPISNOTPROVIDEDFORFURTHERREGULATION OFDELIVERYANDPRESSURE ATTENTION Fluidleakscandamageobjectsandinjurepersons NOTE Never start or stop the pump by connecting or cutting out the power supply Prolonged contact with some fluids can damage the skin The use of goggles and gloves is recommended IF THE PUMP DOES NOT PRIME Depending on t...

Страница 15: ...eign bodies in the suction and delivery circuit of the pump could cause malfunctioning and breakage of the pump components Q MAINTENANCE Safety instruc tions The PUMP IS DESIGNED AND CONSTRUCTED TO require a minimum of maintenance Beforecarryingoutanymaintenancework DISCONNECTTHEPUMPfrom any electrical and hydraulic power source During maintenance the use of personal protective equipment PPE is co...

Страница 16: ...open Use shorter piping or of greater diameter By pass valve blocked Dismantle the valve clean and or replace it Air entering the pump or the suction piping Check the seals of the connec tions A narrowing in the suction piping Use piping suitable for working under suction pressure Low rotation speed Check the voltage at the pump Adjust the voltage and or use cables of greater cross section The suc...

Страница 17: ...theindicationsofdirective 2002 96 CE see text of directive below Information regardingtheenvi ronmentforclients residingwithinthe EuropeanUnion European Directive 2002 96 EC requires that all equipment marked with this symbol on the product and or packaging not be disposed of UPHFUIFS XJUI OPO EJòFSFOUJBUFE VSCBO XBTUF 5IF TZNCPM JOEJDBUFT UIBU this product must not be disposed of together with no...

Страница 18: ......

Страница 19: ...M0217ITEN rev 00 Piusi S p A 46029 Suzzara Mantova Italy www piusi com The Company reserves the right to modify the information contained in this user manual without any prior notice ...

Отзывы: