NOISE LEVEL
Under normal operating conditions, noise emission of all models does not exceed
74 dB at a distance of 1 metre from the electric pump.
S
PROBLEMS AND SOLUTIONS
For any problems contact the authorised dealer nearest to you.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
THE MOTOR IS NOT
TURNING
Lack of electric power
Check the electrical connections
and the safety systems.
Rotor jammed
Check for possible damage
or obstruction of the rotating
components.
Motor problems
Contact the Service Department
THE MOTOR TURNS
SLOWLY WHEN START-
ING
Low voltage in the electric
power line
Bring the voltage back within
the anticipated limits
LOW OR NO FLOW RATE
Low level in the suction tank
Refill the tank
Foot valve blocked
Clean and/or replace the valve
Filter clogged
Clean the filter
Excessive suction pressure
Lower the pump with respect to
the level of the tank or increase
the cross-section of the piping
High loss of head in the delivery
circuit (working with the by-pass
open)
Use shorter piping or of greater
diameter
By-pass valve blocked
Dismantle the valve, clean and/
or replace it
Air entering the pump or the
suction piping
Check the seals of the connec-
tions
A narrowing in the suction
piping
Use piping suitable for working
under suction pressure
Low rotation speed
Check the voltage at the pump.
Adjust the voltage and/or use
cables of greater cross-section
The suction piping is resting on
the bottom of the tank
Raise the piping
INCREASED PUMP
NOISE
Cavitation occurring
Reduce suction pressure
Irregular functioning of the
by-pass
Dispense until the air is purged
from the by-pass system
Presence of air in the fluid
Verify the suction connections
LEAKAGE FROM THE
PUMP BODY
Seal damaged
Check and replace the seal
THE PUMP DOES NOT
PRIME THE LIQUID
Suction circuit blocked
Remove the blockage from the
suction circuit
Malfunction of foot valve fitted
on suction circuit
Replace foot valve
The suction chambers are dry
Add liquid from pump delivery
side
The pump chambers are dirty
or blocked
Remove the blockages from the
suction and delivery valves
THE HEAT SENSOR
ACTIVATES UNDER
NORMAL OPERATING
CONDITIONS
Operating fault
Contact the technical support..