Piusi EX 50 12V Скачать руководство пользователя страница 16

M0217 EN                                            

 

 

 

 

 

      33

EN

NOISE LEVEL

Under normal operating conditions, noise emission of all models does not exceed 
74 dB at a distance of 1 metre from the electric pump.

PROBLEMS AND SOLUTIONS

For any problems contact the authorised dealer nearest to you.

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

THE MOTOR IS NOT 
TURNING

Lack of electric power

Check the electrical connections 
and the safety systems.

Rotor jammed

Check for possible damage 
or obstruction of the rotating 
components.

Motor problems

Contact the Service Department

THE MOTOR TURNS 
SLOWLY WHEN START-
ING

Low voltage in the electric 
power line

Bring the voltage back within 
the anticipated limits

LOW OR NO FLOW RATE

Low level in the suction tank

Refill the tank

Foot valve blocked

Clean and/or replace the valve

Filter clogged

Clean the filter

Excessive suction pressure

Lower the pump with respect to 
the level of the tank or increase 
the cross-section of the piping

High loss of head in the delivery 
circuit (working with the by-pass 
open)

Use shorter piping or of greater 
diameter

By-pass valve blocked

Dismantle the valve, clean and/
or replace it

Air entering the pump or the 
suction piping

Check the seals of the connec-
tions

A narrowing in the suction 
piping

Use piping suitable for working 
under suction pressure

Low rotation speed

Check the voltage at the pump. 
Adjust the voltage and/or use 
cables of greater cross-section

The suction piping is resting on 
the bottom of the tank

Raise the piping

INCREASED PUMP 
NOISE

Cavitation occurring 

Reduce suction pressure

Irregular functioning of the 
by-pass

Dispense until the air is purged 
from the by-pass system

Presence of air in the fluid

Verify the suction connections

LEAKAGE FROM THE 
PUMP BODY

Seal damaged 

Check and replace the seal 

THE PUMP DOES NOT 
PRIME THE LIQUID

Suction circuit blocked

Remove the blockage from the 
suction circuit

Malfunction of foot valve fitted 
on suction circuit

Replace foot valve

The suction chambers are dry

Add liquid from pump delivery 
side

The pump chambers are dirty 
or blocked

Remove the blockages from the 
suction and delivery valves

THE HEAT SENSOR 
ACTIVATES UNDER 
NORMAL OPERATING 
CONDITIONS

Operating fault

Contact the technical support..

Содержание EX 50 12V

Страница 1: ...M0217ITEN rev 00 EX 50 12V ...

Страница 2: ...RST AID RULES 24 G GENERAL SAFETY RULES 25 H TECHNICAL DATA 26 H1 PERFORMANCE SPECIFICATIONS 26 I ELECTRICAL DATA 27 L OPERATING CONDITIONS 27 L1 ENVIRONMENTAL CONDITIONS 27 L2 ELECTRICAL POWER SUPPLY 27 L3 DUTY CYCLE 28 L 4 FLUIDS PERMITTED 28 M INSTALLATION 28 M1 POSITIONING CONFIGURATIONS AND ACCESSORIES 29 M2 NOTES ON SUCTION AND DELIVERY LINES 29 N CONNECTIONS 30 N1 ELECTRICAL CONNECTIONS 30 ...

Страница 3: ...20 M0217 EN EN B MACHINE AND MANUFACTURER IDENTIFICATION AVAILABLE MODELS 12Vdc MANUFACTURER PIUSI S p A Via Pacinotti 16 A z i Rangavino 46029 Suzzara Mantova Italy ...

Страница 4: ...rtly completed machinery Description PumpdesignedforthetransferofFUEL Model PUMPWITHANTI EXPLOSIVEHOUSINGPROTECTIONSYTEM Serial No refer to Lot Number shown on CE plate affixed to product Yearofmanufacture refertotheyearofproductionshownontheCEplateaffixedtotheprod uct Is intended to be incorporated in a machine or to be with other machines so as to create a machine to which applies Machine Direct...

Страница 5: ...s placesintheimmediatevicinityofinadequatelysealedstuffingboxes e g on pumps and valves with stuffing box ZONE 2 Place where it is improbable that an explosive atmosphere made up of a mix of air and inflammable substances in the form of gas vapour or mist can occur during normal operation but which if it does occurs only per sists for a short time Note Said zone can include among others places sur...

Страница 6: ...e appliance with fixed guards tampered with or remo ved 3 To use the appliance in places where there is risk of explosion and or fires classified in the following zones 0 20 21 22 4 Tointegrateothersystemsand orequipmentnotconsideredby the manufacturer in the executive project 5 To connect the appliance up to energy sources other than those contemplated by the manufacturer 6 To use the commercial ...

Страница 7: ...OLTAGES TO CONNECT THE PUMPS ATTENTION PUMPCANNOTBEUSEDFORREFUELLINGAIRCRAFTS SUPPLIEDBYAVGAS ATTENTION USETHEPUMP ONLYWITHFLUIDSPERMITTED DONOTUSEWITHFLUIDSNOTPERMITTEDTOAVOID DAMAGINGTHEPUMP THEGUARANTEELAPSESINCASE OFMISUSEOFTHEFLUID DONOTUSETHEPUMPWITHLIQUIDFOODPRODUCTS AND ORWATER BASEDFLUIDS DONOTOPERATETHEPUMPDRYTOAVOIDDAMAGE Before connection make sure that the piping and the suction tank ...

Страница 8: ...TONATIONOF SPARKS ALLPUMPINGSYSTEMMUSTHAVEPROPER GROUNDING INCLUDINGTANKAND ANYACCESSORIES DANGER ENFORCEREGULATIONSFORELECTRICALINSTALLATION ALL WIRING AND ELECTRICAL CONNECTIONS MUST BE PERFORMED BY AUTHORIZED AND SUITABLY TRAINED PERSONNEL Never touch the electric plug or socket with wet hands Do not switch the dispensing system on if the network connection cable or important parts of the appar...

Страница 9: ...atingconditions Fluid PETROL Temperature 20 C Suctionconditions Thepipeandthepumppositionrelative tothefluidlevelissuchthatalowpressureof0 3baris generatedatthenominalflowrate Underdifferentsuctionconditionshigherlowpressure valuescanbecreatedthatreducetheflowratecompared tothesamebackpressurevalues Toobtainthebestperfor mance itisveryimportanttoreducelossofsuctionpressu reasmuchaspossiblebyfollow...

Страница 10: ...e 89 654 EEC on work environments In case of non EU countries refer to directive EN ISO 12100 2 4 8 6 ATTENTION Thetemperaturelimitsshownapplytothepumpcompo nentsandmustberespectedtoavoidpossibledamageor malfunction L2 ELECTRICAL POWER SUPPLY NOTE The pump must be powered by DC line the nominal values of which are indicated on the table in the paragraph I ELECTRI CAL DATA The maximum acceptable va...

Страница 11: ...ENTHEELECTRICALBOXTOENSUREPROTECTION AGAINSTTHERISKOFEXPLOSION THERIGHTCLAMPINGSCREWSCOUPLETHATGRANTSTHIS PROTECTIONIS10Nm PRELIMINARY INSPECTION Verify that all components are present Request any missing parts from the manufacturer IFDL UIBU UIF QVNQ IBT OPU TVòFSFE BOZ EBNBHF EVSJOH USBOTQPSU or storage Carefully clean the suction and delivery inlets and outlets removing any dust or other packag...

Страница 12: ... pump Forthisreason itisalwaysadvisabletoprimethepumpwithoutanautomaticdeliverynozzle verifying the proper wetting of the pump Always install a foot valve to prevent the suction pipe from being emptied and to keep the pump wet at all times In this way the pump will always start up immediately the next times it is used When the system is in operation the pump can operate with back pressures of up t...

Страница 13: ...s closed be foreswitchingonthepowersupply afterhavingcheckedtheintegrityof the seal gaskets that ensure the IP55 protection grade For those screws use a 10 nm clamping couple ATTENTION Allmotorsareequippedwithagroundingterminal Makesurealltheplantisproperlygrounded ATTENTION BE SURE TO USE A CABLE GLAND WITH SUFFICIENT PROTECTION GRADE Exd NOTE IN THE EVENT OF INSTALLATION IN ZONES WHICH ARE NOT C...

Страница 14: ...akesurethatthepipingandlineaccessoriesareingoodcondition NOTE THISPUMPISNOTPROVIDEDFORFURTHERREGULATION OFDELIVERYANDPRESSURE ATTENTION Fluidleakscandamageobjectsandinjurepersons NOTE Never start or stop the pump by connecting or cutting out the power supply Prolonged contact with some fluids can damage the skin The use of goggles and gloves is recommended IF THE PUMP DOES NOT PRIME Depending on t...

Страница 15: ...eign bodies in the suction and delivery circuit of the pump could cause malfunctioning and breakage of the pump components Q MAINTENANCE Safety instruc tions The PUMP IS DESIGNED AND CONSTRUCTED TO require a minimum of maintenance Beforecarryingoutanymaintenancework DISCONNECTTHEPUMPfrom any electrical and hydraulic power source During maintenance the use of personal protective equipment PPE is co...

Страница 16: ...open Use shorter piping or of greater diameter By pass valve blocked Dismantle the valve clean and or replace it Air entering the pump or the suction piping Check the seals of the connec tions A narrowing in the suction piping Use piping suitable for working under suction pressure Low rotation speed Check the voltage at the pump Adjust the voltage and or use cables of greater cross section The suc...

Страница 17: ...theindicationsofdirective 2002 96 CE see text of directive below Information regardingtheenvi ronmentforclients residingwithinthe EuropeanUnion European Directive 2002 96 EC requires that all equipment marked with this symbol on the product and or packaging not be disposed of UPHFUIFS XJUI OPO EJòFSFOUJBUFE VSCBO XBTUF 5IF TZNCPM JOEJDBUFT UIBU this product must not be disposed of together with no...

Страница 18: ......

Страница 19: ...M0217ITEN rev 00 Piusi S p A 46029 Suzzara Mantova Italy www piusi com The Company reserves the right to modify the information contained in this user manual without any prior notice ...

Отзывы: