CONNECTIONS
N1 ELECTRICAL CONNECTIONS
ATTENTION
BEFORE ANY OPERATION, ENSURE TO BE OUT OF
POTENTIALLY EXPLOSIVE AREAS
IT IS THE INSTALLER'S RESPONSIBILITY TO CARRY OUT THE
ELECTRICAL CONNECTIONS IN COMPLIANCE WITH THE
RELEVANT STANDARDS.
WARNING
Comply with the following (not exhaustive) instructions to
ensure a proper electrical connection:
- During installation and maintenance make sure that power supply to
UIFFMFDUSJDMJOFTIBTCFFOUVSOFEPò
- Use cables with minimum sections, rated voltages and installation type
that are suitable for the characteristics indicated in paragraph "I - ELEC-
TRICAL DATA" and the installation environment.
- Always make sure that the cover of the terminal strip box is closed be-
fore switching on the power supply, after having checked the integrity of
the seal gaskets that ensure the IP55 protection grade. For those screws
use a 10 nm clamping couple
ATTENTION
All motors are equipped with a grounding terminal.
Make sure all the plant is properly grounded.
ATTENTION
BE SURE TO USE A CABLE GLAND, WITH SUFFICIENT
PROTECTION GRADE (Exd)
NOTE
IN THE EVENT OF INSTALLATION IN ZONES WHICH ARE
NOT CLASSIFIED, IT IS SUFFICIENT TO OBSERVE THE MINI-
MUM SAFETY STANDARDS ALREADY MENTIONED IN THIS
MANUAL.
- THE OWNER HAS THE RESPONSIBILITY TO VERIFY THAT
ALL THE LOCAL AND NATIONAL REGULATIONS HAVE BEEN
OBSERVED.
- MAKE SURE THAT THE CABLE CONNECTING THE BATTERY
IS PROTECTED FROM HEAT SOURCES AND SHARP EDGES.
INSTALL THE FUSE CLOSER TO THE BATTERY.
ATTENTION
FAILURE TO OBSERVE THE ABOVE MENTIONED RULES
CAN CAUSE SERIOUS ACCIDENTS
Red Cable +
Black Cable -
GND
Switch
Motor
protector
t°C
1/2” NPT
INLET