TROUBLESHOOTING
Feeding and folding problems are usually due to im prop er ad-
just ment of the machine or to improperly setting up a job. Refer
to the Symptom/Probable Cause section below and the Error
Mes sag es Dis played on the Control Panel table (starting on the
next page) to help you resolve prob lems when operating the
DF500.
Symptom
Probable Cause–Solution
Folder will not run
Line plug loose or pulled
out–attach.
Power switch is off–Turn ON.
Safety cover not completely
closed–close.
Circuit breaker needs to be
reset–reset.
Forms folded improperly
Need to redo setup proce-
dures–page 17.
Forms skew to one side
Infeed guides not set prop-
erly–adjust.
Improper stacking
Form stop bracket not po-
sitioned properly–check job
setup.
Form guides not positioned
properly –adjust.
Rollers do not rotate while
motor is running
Internal problems –contact
Service personnel.
No display
Internal problems–contact
Service personnel.