Pitco SRTE Скачать руководство пользователя страница 2

TO THE PURCHASER, OWNER AND STORE MANAGER

Please review these warnings prior to posting them in a prominent location for reference.

ii

L20-292, rev. 1 (05/11)

WARNING

DO NOT store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.

WARNING

Improper installation, alteration, service or
maintenance can cause property damage, injury or
death. Read the installation, operating and
maintenance instructions thoroughly before installing
or servicing this appliance.

WARNING

Installation, maintenance and repairs should be
performed by a Pitco Authorized Service and Parts
(ASAP) company technician or other qualified
personnel.  Installation, maintenance or repairs by an
unauthorized and unqualified personnel will void the
warranty.

WARNING

Installation and all connections must be made
according to national and local regulations and codes
in force.

WARNING

A country approved all pole circuit breaker with a
minimum open contact gap of 3mm must be used for
proper installation.  (CE countries)

WARNING

During the warranty period if a customer elects to use
a non-original part or modifies an original part
purchased from Pitco and/or its Authorized Service
and Parts (ASAP) companies, this warranty will be
void.  In addition, Pitco and its affiliates will not be
liable for any claims, damages or expenses incurred
by the customer which arises directly or indirectly, in
whole or in part, due to the installation of any
modified part and/or received from an unauthorized
service center.

WARNING

This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.2, as applicable.

WARNING

Adequate means must be provided to LIMIT the
movement or this appliance without depending on the
electrical cord connection.  Single appliances
equipped with legs must be stabilized by installing
anchor straps.  All appliances equipped with casters
must be stabilized by installing restraining chains.

WARNING

DO NOT alter or remove structural material on the
appliance to accommodate placement under a
ventilation hood.

WARNING

This appliance is intended for professional use only
and should be operated by fully trained and qualified
personnel.

WARNING

If the supplied power cord is damaged, it must be
replaced by a Pitco Authorized Service and Parts
(ASAP) company technician, or a similarly qualified
person in order to avoid a hazard.

WARNING

The power supply must be disconnected before
servicing, maintaining or cleaning this appliance.

WARNING

The appliance is NOT jet stream approved.  DO NOT
clean the appliance with a water jet.

WARNING

DO NOT attempt to move this appliance or transfer hot
liquids from one container to another when the unit is
at operating temperature or filled with hot liquids.
Serious personal injury could result if skin comes in
contact with the hot surfaces or liquids.

WARNING

DO NOT sit or stand on this appliance. The
appliance’s front panel, tank, splash back, tank cover,
workshelf, drain board is not a step.  Serious injury
could result from slipping, falling or contact with hot
liquids.

WARNING

NEVER use the appliance as a step for cleaning or
accessing the ventilation hood.  Serious injury could
result from slips, trips or from contacting hot liquids.

WARNING

The water level should be maintained at the level line.
DO NOT turn the appliance on until the heating
elements are fully covered with water at all times.
Serious injury could result from hot steam vapors off
the heating element.

WARNING

If overflow drain is not equipped or if overflow drain
stop is used, do not leave appliance unattended while
filling with water.  Over filling the appliance can cause
serious injuries and damage the equipment.

WARNING

Completely shut the appliance down when the water is
being drained from the appliance. This will prevent the
appliance from heating up during the draining and
filling process.  Serious injury and heating element
damage can occur.

WARNING

This appliance is intended for indoor use only.

WARNING

DO NOT operate appliance unless all panels and
access covers are attached correctly.

WARNING

It is recommended that this appliance be inspected by
a qualified service technician for proper performance
and operation on a yearly basis.

Содержание SRTE

Страница 1: ...EFERENCE Please complete this information and retain this manual for the life of the equipment Model ___________________________ Serial ___________________________ Date Purchased ____________________...

Страница 2: ...NING DO NOT alter or remove structural material on the appliance to accommodate placement under a ventilation hood WARNING This appliance is intended for professional use only and should be operated b...

Страница 3: ...MS 5 1 7 INSPECTION 5 1 8 INITIAL CLEANING 5 2 OPERATION 6 2 1 FILLING THE APPLIANCE 8 2 1 1 FILLING THE COOKER TANK 8 2 1 2 FILLING THE COOKER TANK WITHOUT THE AUTOMATIC LEVEL SYSTEM 8 2 2 APPLIANCE...

Страница 4: ...INSPECTION 12 3 3 1 HEATING ELEMENT 12 3 3 2 TEMPERATURE PROBE HIGH LIMIT PROBE 12 3 3 3 CONTROLLER 12 3 3 4 CONTROL BOX ELECTRICAL COMPONENTS 12 3 3 5 TANK 13 3 3 6 DRAIN SYSTEM 13 4 TROUBLESHOOTING...

Страница 5: ...our appliance to ensure that you have received all the parts to the appliance If you are missing any parts contact the dealer from whom the appliance was purchased As you unpack the appliance and its...

Страница 6: ...screws are tight 3 Mount the screws from the inside of the appliance with the nut on the outside bottom of the appliance The nuts have lock washers attached to them therefore it is not necessary to u...

Страница 7: ...her water pressures a high pressure regulator must be installed to inlet plumbing to avoid damage caused by water hammer The maximum allowable incoming water temperature is 180 F 82 C Have your water...

Страница 8: ...tallations In all other cases refer to local and national codes and regulations To comply with European requirements European models are equipped with an equalization bonding clamp An equalization bon...

Страница 9: ...thin coat of oil for protection Before the appliance is ready for cooking it must be cleaned This will remove the oil coating and any foreign matter that may have accumulated during storage and shipme...

Страница 10: ...control type should be included with this manual Refer to that manual prior to operating this appliance 2 1 OPERATIONAL FEATURES The diagram below outlines some of the key operational components of yo...

Страница 11: ...is button may need to be pressed in the event that the high temperature limit has tripped 8 Tank Cover shown in UP position Keeps heat inside and debris outside of the cook tank 9 Tank Cover Latch Hol...

Страница 12: ...water level sensors are covered the solenoid valve will close stopping the flow of water During normal operation the automatic fill system will maintain the water level at the proper height NOTE If th...

Страница 13: ...f water to minimize the chance of boiling the appliance dry and to keep the water at a level that will provide optimum cooking performance To ensure the quality of the food you cook in this appliance...

Страница 14: ...follow the food manufacturer s directions and only use vacuum sealed products in this appliance Some products can be reheated and held at the same temperature If this is the case the product may be he...

Страница 15: ...t and temperature probe using a Scotchbrite or other abrasive pad with a commercial type cleaner specifically designed for cleaning and sanitizing food contact surfaces Follow the directions and famil...

Страница 16: ...eck that the insulation is dry Verify that bulkhead connections nut is tight and leak free Look for water stains and wet surfaces Verify amp draw is within range as compared to the information on the...

Страница 17: ...that tank is leak free Check drain overflow if equipped for scale build up and debris blockage 3 3 6 DRAIN SYSTEM Verify that drain valve is in good condition Check for leaks in the seal area and fitt...

Страница 18: ...time to cool to room temperature 3 Add water to the cook tank as needed 4 Press the high temperature reset button if equipped 5 The high limit switch is now reset and the appliance is ready for start...

Страница 19: ...r is wet Dry off sensor Dirty upper water level sensor Clean upper water level sensor Autofill does not shut off when full Insufficient mineral content in water Add 1 8 cup baking soda to cook tank Au...

Страница 20: ...de Website Address www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area...