Pitco SRTE Скачать руководство пользователя страница 16

PREVENTATIVE MAINTENANCE

12

L20-292, rev. 1 (05/11)

WARNING

The power supply must be
disconnected before cleaning
and servicing this appliance!

3.2.  MONTHLY PREVENTATIVE MAINTENANCE

Water can leave mineral deposits inside the tank.  Performing the monthly preventative maintenance
steps below will keep your equipment safe and at peak performance. It may be necessary to clean
these components more then once a month.

3.2.1. DELIMING

1.  Read the “operation” section of this manual prior to filling or operating the appliance.

2.  Following the manufacturer’s deliming instructions, remove deposits from the tank’s interior.

3.  When cleaning is complete, rinse the inside of the tank and its components thoroughly with

cool water.  Continue to rinse at least twice or until the cleaner has been completely and
thoroughly rinsed from the tank.

4.  Using a clean dry cloth, wipe out all of the water.

3.3. ANNUAL/PERIODIC 

PREVENTATIVE MAINTENANCE AND INSPECTION

This section should ONLY be performed by a qualified service technician as part of a regular kitchen
maintenance program.  This inspection should take place a minimum of once a year by an Authorized
Service Technician recommended by Pitco. It may be
necessary perform this inspection more then once a year.

3.3.1. HEATING 

ELEMENT

  Check if the element is mechanically strong and in

good condition.  Look for scale build up and inspect for
signs of repeated dry firing.

  Verify element wires are in good working condition.  Look for damage to wires or frayed

insulation.  Check that the insulation is dry.

  Verify that bulkhead connections/nut is tight and leak free. Look for water stains and wet

surfaces.

  Verify amp-draw is within range as compared to the information on the data plate.

3.3.2.  TEMPERATURE PROBE & HIGH LIMIT PROBE

  Verify probes are in good working condition.  Check for damage and that the fasteners are

tightly secured to the tank.

  Verify compression fittings are leak free.

  Check wiring for loose electrical connections.

3.3.3. CONTROLLER
Perform the following inspection if the appliance is equipped with a temperature controller.

  Verify that the controller is in good mechanical condition.  Check all lights, displays and

switches to assure that they are working properly.  Examine overlay for damage that could
allow moisture to enter.

  Check for loose electrical connections.

  Verify simmer temperature.  Check temperature 1” above controller probe, if necessary check

probe resistance.

  Check drain valve interlock (if provided) to ensure that the appliance stops heating when the

drain valve is open.

3.3.4.  CONTROL BOX & ELECTRICAL COMPONENTS

  Verify that heating contactors are in good condition.  Check for worn or pitted contacts.  Verify

that wires are tight and in good condition.

  Verify that all components (transformer, terminal block, relays, drain switches, etc…) are in

good condition.  Verify that wires are tight and in good condition.

  Verify enclosures are free of leaks.  Check for water stains and wet surfaces.

  Verify that the covers and panels are in tact and provide a safe condition.  Check for loose

parts.

  Verify power cord is in good condition.  Check for frayed or exposed wires.  Verify that the

insulation is in good condition and the attachment to the appliance is tight.

Содержание SRTE

Страница 1: ...EFERENCE Please complete this information and retain this manual for the life of the equipment Model ___________________________ Serial ___________________________ Date Purchased ____________________...

Страница 2: ...NING DO NOT alter or remove structural material on the appliance to accommodate placement under a ventilation hood WARNING This appliance is intended for professional use only and should be operated b...

Страница 3: ...MS 5 1 7 INSPECTION 5 1 8 INITIAL CLEANING 5 2 OPERATION 6 2 1 FILLING THE APPLIANCE 8 2 1 1 FILLING THE COOKER TANK 8 2 1 2 FILLING THE COOKER TANK WITHOUT THE AUTOMATIC LEVEL SYSTEM 8 2 2 APPLIANCE...

Страница 4: ...INSPECTION 12 3 3 1 HEATING ELEMENT 12 3 3 2 TEMPERATURE PROBE HIGH LIMIT PROBE 12 3 3 3 CONTROLLER 12 3 3 4 CONTROL BOX ELECTRICAL COMPONENTS 12 3 3 5 TANK 13 3 3 6 DRAIN SYSTEM 13 4 TROUBLESHOOTING...

Страница 5: ...our appliance to ensure that you have received all the parts to the appliance If you are missing any parts contact the dealer from whom the appliance was purchased As you unpack the appliance and its...

Страница 6: ...screws are tight 3 Mount the screws from the inside of the appliance with the nut on the outside bottom of the appliance The nuts have lock washers attached to them therefore it is not necessary to u...

Страница 7: ...her water pressures a high pressure regulator must be installed to inlet plumbing to avoid damage caused by water hammer The maximum allowable incoming water temperature is 180 F 82 C Have your water...

Страница 8: ...tallations In all other cases refer to local and national codes and regulations To comply with European requirements European models are equipped with an equalization bonding clamp An equalization bon...

Страница 9: ...thin coat of oil for protection Before the appliance is ready for cooking it must be cleaned This will remove the oil coating and any foreign matter that may have accumulated during storage and shipme...

Страница 10: ...control type should be included with this manual Refer to that manual prior to operating this appliance 2 1 OPERATIONAL FEATURES The diagram below outlines some of the key operational components of yo...

Страница 11: ...is button may need to be pressed in the event that the high temperature limit has tripped 8 Tank Cover shown in UP position Keeps heat inside and debris outside of the cook tank 9 Tank Cover Latch Hol...

Страница 12: ...water level sensors are covered the solenoid valve will close stopping the flow of water During normal operation the automatic fill system will maintain the water level at the proper height NOTE If th...

Страница 13: ...f water to minimize the chance of boiling the appliance dry and to keep the water at a level that will provide optimum cooking performance To ensure the quality of the food you cook in this appliance...

Страница 14: ...follow the food manufacturer s directions and only use vacuum sealed products in this appliance Some products can be reheated and held at the same temperature If this is the case the product may be he...

Страница 15: ...t and temperature probe using a Scotchbrite or other abrasive pad with a commercial type cleaner specifically designed for cleaning and sanitizing food contact surfaces Follow the directions and famil...

Страница 16: ...eck that the insulation is dry Verify that bulkhead connections nut is tight and leak free Look for water stains and wet surfaces Verify amp draw is within range as compared to the information on the...

Страница 17: ...that tank is leak free Check drain overflow if equipped for scale build up and debris blockage 3 3 6 DRAIN SYSTEM Verify that drain valve is in good condition Check for leaks in the seal area and fitt...

Страница 18: ...time to cool to room temperature 3 Add water to the cook tank as needed 4 Press the high temperature reset button if equipped 5 The high limit switch is now reset and the appliance is ready for start...

Страница 19: ...r is wet Dry off sensor Dirty upper water level sensor Clean upper water level sensor Autofill does not shut off when full Insufficient mineral content in water Add 1 8 cup baking soda to cook tank Au...

Страница 20: ...de Website Address www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area...