background image

INSTALLATION & START-UP 

Location 

For proper operation and maximum performance, locate the Crisp n’ 
Hold in an ambient air temperature of 70º F (21ºC). 

 

Avoid areas near exhaust fans where there is active air movement. 
For safe operation, locate the unit a reasonable distance from com-
bustible walls and materials. 

 

To prevent injury and damage, locate the unit at a proper and safe 
working height.  The location should be level, clean of debris, and 
strong enough to support the weight of a fully loaded unit. 

 

Start-up 

1.  Plug the Crisp n’ Hold into a properly grounded electrical recep-

tacle. 

2.  Ensure all plastic and packaging materials have been removed. 

3.  Familiarize yourself with the controls. 

4.  On/Off switch is located inside the cabinet below the product 

station.  Set POWER switch to “ON” position. 

5.  Do not load product into the cabinet.  Allow the heat to remove 

any residual oils which may adhere to inside metal surfaces.  A 
slight emission of smoke is normal for the first few hours of 
operation. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GROUNDING INSTRUCTIONS 

This appliance is equipped with a cord having a grounding 
wire with a grounding plug which must be plugged into an 
outlet that is properly installed and grounded.  In the event of 
an electrical short circuit, grounding reduces the risk of elec-
tric shock by providing an escape wire for the electric current. 

 

WARNING—Improper use of the grounding can result in 
a risk of electric shock.

  Consult a qualified electrician or 

serviceman if the grounding instructions are not completely 
understood, or if doubt exists as to whether the appliance is 
properly grounded.

 

5

WARNING: 

Risk of personal injury 

 

Installation procedures must be 
performed by a qualified technician 
with full knowledge of all applicable 
electrical codes. 
 
Failure can result in personal injury 
and property damage. 

 

IMPORTANT: 

Power cord is 7' long. 

If necessary, contact a licensed 
electrician to install an appropriate 
20 amp electrical circuit with correct 
NEMA receptacle. 

 

CAUTION: 

Electrical Shock Hazard 

 

The ground prong of the power cord 
is part of a system designed to pro-
tect you from electric shock in the 
event of internal damage. 

DO NOT cut off the large round 
ground prong or twist a blade to fit 
an existing receptacle. 

 

IMPORTANT: 
Not under warranty: 

Damage to unit due to being 
connected to the wrong voltage or 
phase is 

NOT 

covered by warranty. 

 

CAUTION: 

Risk of personal injury 

 

Unit is not waterproof, to avoid 
electrical shock keep unit and 
counter from being submerged in 
water.  Do not operate if unit has 
been submerged in water. 

Содержание CRISP N' HOLD PCF14

Страница 1: ...NSPECTION 4 INSTALLATION START UP 5 NORMAL OPERATION 6 CONTROLLER PROGRAMMING 6 DAILY CLEANING PROCEDURES 7 WIRING DIAGRAMS REPLACEMENT PARTS 8 TROUBLESHOOTING GUIDE 9 WARRANTY STATEMENT 10 Part Numbe...

Страница 2: ...c This equipment is not designed for industrial or laboratory use 4 Cleanliness of this appliance and accessories is essential to good sanitation 5 DO NOT submerge this appliance in water This applian...

Страница 3: ...access Capacity Dimensional Characteristics Layout Two models with adjustable and removable dividers 14 with 2 sections 18 with 3 sections Internal Capacity cubic inches PCF14 837 2 sections PCF18 105...

Страница 4: ...n company assumes full responsibility for its safe delivery IF SHIPMENT ARRIVES DAMAGED 1 VISIBLE LOSS OR DAMAGE Be certain that any visible loss or damage is noted on the freight bill or express rece...

Страница 5: ...lled and grounded In the event of an electrical short circuit grounding reduces the risk of elec tric shock by providing an escape wire for the electric current WARNING Improper use of the grounding c...

Страница 6: ...perature set button To change the temperature setpoint press and hold the temperature set button press the up or down arrow button until the desired air temperature is displayed The display will adva...

Страница 7: ...inish Water with high chlo ride content can also damage stainless steel If unsure of your water quality we recommend you have it tested THIS DAMAGE IS PERMANENT COSTLY TO REPAIR AND IS NOT COV ERED BY...

Страница 8: ...0 0061 THERMAL DISC AUTO RESET X X X 18612 0113 TUBULAR ELEMENT 900W 120V X X X 18616 0223 RELAY SPST NO 240V 24VAC X X X 18616 0229 CONTROL WGRN LGHT ROHS X X X 18312 0189 CONTROL OVERLAY X X X 18602...

Страница 9: ...tch damaged or defective Check replace if required Food dries out too quickly Operation where product temp is too high Check product temps going into hold ing cabinet Thermostat incorrectly set or def...

Страница 10: ...ates and Canada this warranty is limited to the replacement of parts and Pitco Frialator Inc will not bear any other expense be it labor mileage freight or travel If any oral statements have been made...