14
15. Remove the lower rear back cover.
16. Unscrew the compression fitting at the rear of
the tank.
17. Remove the air tube from the air box (the blower
is mounted to this box).
18. Grasp the tank by the middle tube and remove it
from the rear of the cabinet.
Split Fry Tanks-
Split Fry Tanks should be removed and installed as
pairs in the same manner as Full Fry Tanks. There
are 3 sets of clamps that hold the two Split Fry Tanks
together:
1. On the rear of the tank.
2. On the bottom of the tank accessed by first re-
moving the blower.
3. On the bottom of the tank at the front.
NOTE:
To disconnect the filter return piping (as in
step # 15) unscrew the union connecting the return
piping to the tanks.
Install in the reverse order.