COMPONENT CHANGEOUT
It is assumed that for all (except where noted) of these
component changeout instructions the fryer has been
shut down and disconnected from the power and gas
supplies, cooled and drained of oil.
Probes:
1. Unplug the wiring connector.
2. Unscrew the small nut on the probe seal.
3. Slide the probe from the seal.
Install in the reverse order using the new ferrule
supplied with the new probe.
Hi Limits:
1. Unplug the wiring connector.
2. Unscrew the Hi Limit from the front of the fry
tank.
Install in the reverse order.
Computers:
CAUTION:
Take care not to drop any of the components from
the front panel as this will damage them.
1. Remove the two screws from the upper mount
of the front panel.
2. Unplug the wiring connection at the rear of the
computer.
NOTE:
On split tank machines you will find 2 wir-
ing connections to unplug.
Install in the reverse order.