12
2. The sensor may be removed by disconnecting
the wiring harness and by removing the 2 mount-
ing screws.
Install in the reverse order.
Blowers:
1. Unplug the wiring connector.
2. Remove the 3 screws from the mounting flange.
3. Using a flat screwdriver, break the seal at the
motor flange.
4. The motor can now be lowered out of the ma-
chine.
NOTE:
The new blower will be shipped with the
blower housing attached. Remove the motor from
the blower housing in the above manner. Clean the
sealant from the new motor and the old housing (still
attached to the machine). Apply a small amount of
high temperature silicone sealant to the motor mount-
ing flange.
Install the motor in the reverse order of removal.
Pressure Switches:
1. Unscrew the plastic fitting from the air connec-
tion on the pressure switch.
2. Unplug the 2 wires from the switch.
3. Remove the 2 screws from the mounting bracket.
Install in the reverse order.
Fry Tanks:
Full Fry Tanks-
1. Remove ALL of the computer/controllers from
the machine.
2. Remove the burners and ignitors from the tank
to be removed.
3. Disconnect the drain valve switch wires.
4. Disconnect the return valve switch wires.
5. Disconnect the blower wires.
6. Remove the drain line from the left and right ends
of the drain valve tee.
7. Disconnect the filter return piping at the rear of
the Fry Tank.
8. Remove the 3 screws from the front of each unit.
Содержание AG14S
Страница 4: ...ii...
Страница 6: ...iv...
Страница 10: ...4 Split Vat Fryers LADDER DIAGRAMS Full Vat Fryers...
Страница 24: ...18...
Страница 25: ...19...
Страница 27: ...1 AG14 FRYER PARTS BREAKDOWN...
Страница 29: ...3...
Страница 31: ...5 1 2 3 4 5 6 7 8 9 10 11 13 13...
Страница 33: ...7 SEE DETAIL A SEE DETAIL A 2 3 4 1 5 6 7 8 9 10 11 14 12 13 15...
Страница 35: ...9...
Страница 37: ...11...
Страница 39: ...13 3 7 8 10 12 13 2 4 5 6 9 11 1...
Страница 41: ...15...