ENGLISH
28
K(Black)
W(White)
R(Red)
Y(Yellow)
P(Purple)
O(Orange)
G(Green)
K
K
R
W
o
W
G
P
R
W
Y
R
Y
W
FUEL INPUT
RATING:
2.0 KG/H
(4.4 LB/H)
INDEX
K : BLACK
W : WHITE
R : RED
Y : YELLOW
P : PURPLE
O : ORANGE
G : GREEN
ELECTRICAL WIRE DIAGRAM
The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60HZ, 275W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
LOCATE AND REMOVE
THE EIGHT SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
IGNITOR ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V, 2.6 AMP
9.5MM X 127MM (0.375” X 5.000”)
DRAFT FAN
120V, 50/60HZ,
0.1 AMP, 1 PHASE
LIGHT
25W, 120V
GROUNDED POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
AUGER MOTOR
& FEED SYSTEM
120V, 50/60HZ,
0.22 AMP, 2 RPM MOTOR
GROUND
GRILL PROBE
CONTROL BOARD