![Pisector GSM-01 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/pisector/gsm-01/gsm-01_user-manual_1559173006.webp)
O3 (SPEAKER):
This port is for voice output, it can be connected to the speaker. The
other port of the speaker is to connect to ground. You can control it by
call in or send the SMS.
RELAY1, RELAY2:
These two ports will close 3 minutes when alarm happens. You can use
these two ports to start the power supply of the camera when alarm
happens, also you can disable this function by setting command 16#1#,
you can also make this relay close or open anytime by sending SMS or
dialing (94#1# or 94#0#).
Wiring Explanation: For home-appliance control (for special order)
The controller box has four wires:
i).
Two yellow AC 220 wires to be connected with Home appliance.
ii)
. GND, +12V DC wires to be connected with a 12V DC (Power
supply)
NOTE:
Try to install the main panel in the center of defense zone and pull
out the antenna to get longer wireless receiving distance.
Installation position should be far away from huge metal objects
and wireless interference.