II.  Installation 

1.  Host 

a. 

  Insert SIM card in alarm system

 

Press the yellow point on the unit with a pencil tip or other tools, SIM 

card tray will come out. Put the SIM card into the tray and make sure 

the  Metal contacts of the card to  be downwards,  and then push the 

tray back. 

Before  inserting  SIM  card  in  the  alarm  unit,  using  a  regular  mobile 

phone do the following steps: 

---Set PIN code request to off 

---Delete all stored numbers 

 

b.  Connect the antenna 

Screw

 

the antenna to the unit carefully; do not over-tighten the nut 

or leave it too loose! 

c.  Connect the power supply 

Plug  the  alarm  system  into  power  and  turn  on  the  power  switch.  The 

signal status LED on the unit will turn red and last for 20 seconds. This 

shows it’s waiting for wireless detectors to be coded into the unit. Then 

the status LED will turn orange with flash, indicating the unit is checking 

the SIM card and searching for GSM network. After checking, if the LED 

changes to green with slow flash, it shows phone numbers have been 

saved in the unit, and the unit is now in “Arm” status. If the LED keeps in 

green, it means phone numbers have  not  been saved in the unit, and 

the unit is in “Disarm” status, you can call in or send SMS to program 

the phone numbers.   

Содержание GSM-01

Страница 1: ...Wireless GSM Alarm System GSM 01 User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it ...

Страница 2: ...or environment on the spot 7 Voice and message alert 8 5 group phone room number 1 group alarm monitor center phone 9 2 group phone to report alarm and non alarm status 10 Can program 7 group alarm messages 11 Easy to set ON or OFF for every wired or wireless detector 12 1 relay output to trigger camera when alarm 13 2 output for home appliances connection lamp cooker air condition 14 SMS alert fo...

Страница 3: ...en the nut or leave it too loose c Connect the power supply Plug the alarm system into power and turn on the power switch The signal status LED on the unit will turn red and last for 20 seconds This shows it s waiting for wireless detectors to be coded into the unit Then the status LED will turn orange with flash indicating the unit is checking the SIM card and searching for GSM network After chec...

Страница 4: ...rm status Normal working Red flash slowly In alarm status Red flash quickly Remote controlled by SMS commands or phone Green Disarm Green flash slowly Out Arm Green flash quickly Home Arm MONITOR On Can monitor the scene when alarming but the siren will not ring Off Can not monitor the scene when alarming but the siren will ring ALARM On The siren will ring when alarming Off The siren will not rin...

Страница 5: ...ors can be NO normally Open or NC normally Close type More than 1 sensor can be connected to one input connect their alarm contacts in series The number of the sensors is not limited as long as the total resistance is under 220 ohms O1 O2 These 2 ports for output you can call in or send SMS to set them If output of these goes high the light of OUT 1 or OUT 2 will light on the panel non specialist ...

Страница 6: ...tion by setting command 16 1 you can also make this relay close or open anytime by sending SMS or dialing 94 1 or 94 0 Wiring Explanation For home appliance control for special order The controller box has four wires i Two yellow AC 220 wires to be connected with Home appliance ii GND 12V DC wires to be connected with a 12V DC Power supply NOTE Try to install the main panel in the center of defens...

Страница 7: ...etector PIR detectors are used to detect the movement within a certain range Fix the adjustment bracket on the wall with the provided screws and attach the detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor Effect of the PIR detection is best when the detection direction is in 90 angle with the walking direction of the intruder Choose the most suitable inst...

Страница 8: ...mber 13905950001 into the base 2 There are 7 default SMS contents in the base but you can change it When the wireless detector in zone 01 to 05 is triggered the default SMS content will be Wireless Activated X X can be 01 to 05 For example if detector in zone 01 is triggered the SMS will be Wireless Activated 01 When the wireless detector in zone 06 to 16 is triggered the default SMS content will ...

Страница 9: ...en you can use controller to change the base into Arm status or you can send SMS 123456 1 1 to the base to change the base into Arm status the signal LED will change to flashing green 1 Under Arm status with green LED on any port of input I1 I2 I3 short circuit or disconnected or any wireless detectors has been activated or you press the emergency key on the controller the alarm system will send a...

Страница 10: ...status 5 When there is alarm you can use the controller to change the base into disarm status when you are in nearby can control the situation 6 When the external power is cut off the system will send SMS Power changer off to inform When the external power recovered the system will send SMS Power changer on to inform V Control the host 1 Send message to the host phone number SIM Card number Send m...

Страница 11: ...n sound when alarming 11 0 No siren sound when alarming 12 1 Send SMS when alarming 12 0 No SMS when alarming 15 1 Dial phone number when alarming 15 0 Just alarm and no dialing 16 1 Relay does not close for 3 Min when alarming 16 0 Set Relay close for 3 Min when alarm 21 1 Siren rings when pressing out arm button 21 0 Siren off when pressing out arm button 22 1 Siren rings when pressing home arm ...

Страница 12: ...ess zone 1 16 wire zone 21 23 50 show preset phone numbers in the host SMS command applicable only 51 First group phone number 0 15bit 52 Second group phone number 0 15bit 53 Third group phone number 0 15bit 54 fourth group phone number 0 15bit 55 Fifth group phone number 0 15bit 80 show preset SMS in the host 81 Wireless zone 01 Message 0 24bit 82 Wireless zone 02 Message 0 24bit 83 Wireless zone...

Страница 13: ...ine input 2 connect to GND 97 1 Set alarm when line input 3 open 97 0 Set alarm when line input 3 connect to GND Note 1 In the above table stands for default setting 2 Alarm delay is not workable for smoke detector gas detector or emergency button That is even though this system is set as alarm delay triggering of the mentioned sensors will cause immediate alarm without delay 3 In alarm delay stat...

Страница 14: ...e a reply message for confirmation after you send the message command to the base the replied message for example Disarm Sms ON Phone ON Siren ON Center Tel OFF Arm Center Tel OFF Disarm Center Tel OFF You will know the working state of the base then arm disarm or alarm VI Remote controllers The remote controller has four buttons 1 Out Arm Out Arm Emergency Home Arm Disarm ...

Страница 15: ...it will turn green with fast flash Detectors inside the house in inner defense zone will not work only the detectors outside the house in outside defense zone will work so that people inside can move freely but others who break in from outside will trigger the alarm 3 Disarm Press Disarm button the system will enter into disarmed status the STATUS indicator on the main panel is green 4 Emergency W...

Страница 16: ... enters into working mode status LED light on panel will change to yellow then to green 2 Add sensors into inner defense zone Detectors in this zone are ready to work when you set Out Arm and will not work when you set Home Arm When the GSM host begins to be powered on the status LED light on panel will be red Push the reset button for one second the status LED light will light up in orange for 20...

Страница 17: ...f these detectors so that they can not control your alarm system Keep pressing the reset button then power on the system One beep sound or LED flashes shows reset is successful All registered detectors have been deleted from the unit You can register them again with the above mentioned procedures System reset will not change the SMS message Basic Kit Main Panel 1 pc Wireless PIR detector 1 pc Wire...

Страница 18: ...The following sensors are optional Optional sensors detectors are packed separately You can choose according to your specific requirements ...

Страница 19: ...y 433MHZ Wireless distance 100 M Wireless detectors 16 Wire detectors 3 Wireless Gap Detector Door Window Contact Power Supply DC12V inner 7 4V battery Static Current 20 uA Transmission Current 15mA Transmission Frequency 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Internal Distance 15 mm Working Condition Temperature 10 40 Humidity 90 rh ...

Страница 20: ...ve Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 40 Humidity 90 rh Remote Controller Power Supply DC 12V 8 4 Inside A23 DC 12V dry battery Static Current 0 Emission Current 15 mA Emission Frequency 433 0 2 MHz Emission Speed T 1 second Emission Distance no obstacle 80m Working Environment Temperature 10 40 Humidity 90 ...

Страница 21: ...number again according to the manual 4 Adjust the installation place of the door sensor 5 Activate the PIR 6 Check code again Remote controlling distance is too short and the light indicator is not on bright enough 1 The battery of remote controller is rusty 2 Low battery 1 Clean the rust 2 Change battery Light indicator of door sensor and PIR is always on Low power battery Change battery Dial ala...

Страница 22: ...ry 2 There is block between the control panel and the wireless accessory or the distance between them is too far 3 The accessory has not been coded to the panel 1 Replace the battery 2 Pull out the antenna of the accessory and the main panel and adjust the position 3 Code it to the main panel ...