PDP-R06XE
54
1
2
3
4
1
2
3
4
C
D
F
A
B
E
6.5 LIST OF RS-232C COMMANDS (MEDIA RECEIVER)
RS-232C commands can be used in Service Factory mode. Before using RS-232C commands, it is necessary to change the factory
presetting. See " 6.2 USING RS-232C COMANDS".
Refer to the service manual of the PDP506P/406P for the panel command.
[ Note : If you want to see version information (ex. QS1, QS6, Factory, Menu), Please see 10 seconds after starting. ]
Command Operation
Remarks
B
BSL
Adjust side mask B
C
CNG
Clearing MR NG information
CHR
Clearing MR Hour meter
D
DW*
Decreasing the adjustment value by*
*:1-9, 0(0 means 10),F(making the adjustment value the minimum)
F
FAN
Turning Service Factory mode off.
FAY
Turning Service Factory mode on.
FST
Final Set Up
G
GSL
Adjust side mask side mask G
I
INA
Selection of tuner for terrestrial analog signals.
INC***
Selection of tuner for terrestrial digital signals
INH
Selection of SD card/PCMCIA card
INPS01
Input selection: input 1
INPS02
Input selection: input 2
INPS03
Input selection: input 3
INPS04
Input selection: input 4
INPS05
Input selection: input 5
INPS06
Input selection: input 6
PDP-R06XE only
PDP-R06XE only
PDP-R06XE only
PDP-R06XE only
O
OSDS00
Turning the On-Screen Display off
Permit On-Screen Display.
OSDS01
Turning the On-Screen Display on
Prohibit On-Screen Display.
P
POF
Turning the power off.
PON
Turning the power on.
Q
QS1
Obtaining the version data for each device.
QS6
Obtaining the any version.
QMT
Obtaining the MR temperature information.
QNG
Obtaining NG data of the MR.
R
RSL
Adjust side mask side mask R
U
UP*
Increasing the adjustment value by *
*:1-9, 0(0 means 10),F(making the adjustment value the maximum)
Z
ZME
Initializing of the EEPROM video data