PDP-R06XE
41
5
6
7
8
5
6
7
8
C
D
F
A
B
E
6.4 SERVICE FACTORY MODE
To operate in Service Factory mode, use the supplied remote control unit.
Remote control codes in Service Factory mode
SR Function
Main Function
Remarks
Muting
Switching the main items
Shifting to the next main item (top)
DOWN
Switching the subtitled items
Shifting downward to the next subtitled item
UP
Switching the subtitled items
Shifting upward to the next upper layer
LEFT
Increasing the adjustment
value
Increasing the adjustment value
RIGHT
Decreasing the adjustment
value
Decreasing the adjustment value
SET
Switching layers
Shifting downward or upward to the next lower or upper
layer
INPUT
Selecting input
Shifting the input to the next function
INPUTxx
Selecting input
Switching the input to xx
CH+
Increasing the channel
number
Advancing a preset channel
(effective when Function is set to TV)
CH-
Decreasing the channel
number
Turning a preset channel backward
(effective when Function is set to TV)
Numeric keys
Function: TV
Function: TV
(previously selected channel number is selected)
POWER
Power OFF
Turning the power off
FACTORY
Factory OFF
Turning Service Factory mode off
MENU
Menu ON
Turning Service Factory mode off and Menu mode on
Operation in Service Factory mode
How to enter Service Factory Mode
¶
Functions whose settings are set to OFF
The settings for the following functions are set to OFF when Service Factory mode is entered (including when the "FAY"
command is received):
• Two-screen operations (input function set on the main side is selected)
• P ZOOM
• FREEZE
• Detection of the TRAP switch (The log in the EEPROM is retained.) (KUC type only)
¶
User data
User data will be treated as follows:
• User data on picture- and audio-quality adjustments are not reflected, and factory-preset data are output (user data will be
retained in memory). When the unit enters Factory mode, the current audio-quality adjustment data will still be retained in
memory.
• As to data on various settings, user data will be applied to the items that are associated with signal format change (screen
size switching, etc.).
• Data on screen (i.e., screen position; meaning clock dividers, and not including data on screen size) are reset to the default
values (data stored in memory will be retained). Screen size will be retained.
While in Standby mode, follow the below procedures with the remote control to enter Service Factoy mode.
1. Press the [ DISPLAY ] key.
5. Before 5 second counter ends, press [ UP ] key.
2. 3 second counter will start.
6. Before 5 second counter ends, press [ LEFT ] key.
3. After 3 seconds, press [ LEFT ] key.
7. Before 5 second counter ends, press [ RIGHT ] key.
(If no operation is done within 10 seconds, the Service
8. Before 5 second counter ends, press [ POWER ] key.
Factory routine is cleared, and the standby mode is returned) 9. If the prodcedure is correct with the given time, the
4. 5 Second counter will start.
Service Factory mode is up and ready.
* During step 3 to 8, if other operations took place, the Service Factory routine is cleared.
* If the counter's time is up, normal standby mode is returned.