PDP-R06XE
56
1
2
3
4
1
2
3
4
C
D
F
A
B
E
QNG:
Returning data (logs keep on Main microcomputer) on shutdown of Media Receiver.
• Details on the NG data and subcategory
• Data on Subcategories for failure in 3-wire serial communication of Main microcomputer (subcategory 1)
Order
Data
Size
Context
0
Received Command Name on MR
3 byte
'QNG' only
1
Latest NG data
1 byte
2
Data of subcategory for the latest NG
1 byte
3
Data of MR hour meter for the latest NG
7 byte
4
Data of temperature for the latest NG
3 byte
5
2nd latest NG data
1 byte
6
Data of subcategory for the 2nd latest NG
1 byte
7
Data of MR hour meter for the 2nd latest NG
7 byte
8
Data of temperature for the 2nd latest NG
3 byte
:
:
:
29
7th latest NG data
1 byte
30
Data of subcategory for the 8th latest NG
1 byte
31
Data of MR hour meter for the 8th latest NG
7 byte
32
Data of temperature for the 8th latest NG
3 byte
Data
Cause of Shutdown
Remarks
0
Normal
1
Failure of communication to Module microcomputer
2
3-wire Serial Communication of Main microcomputer.
Subcategory
⇒
1
3
IIC Communication failure of Main microcomputer
Subcategory
⇒
2
4
Communication failure of Main microcomputer &Unknown Error
5
Fan stopped
6
Abnormally high temperature at MR.
7
Failure of Digital Tuner
Subcategory
⇒
3
8
Abnormally in RST2 of MR(power decrease of DC-DC converter)
9
Failure at Home Gallary
Subcategory
⇒
4
Data
Cause of Shutdown
Remarks
0
Non subcategory
1
Communication failure of IF microcomputer
Power OFF
2
MANTA communication failure(MULIT1)
Power OFF
3
MANTA communication failure(MULIT2)
Reserved
4
MANTA communication failure(I/P)
5
MANTA communication failure(D-SEL)