DataMan2
Operating Instructions
DataMan2_OI_104.doc
Page 14 of 35
The left portion of the window shows a comprehensive list of all commands in the
current stack. The right side of the window provides methods to create, change and
delete commands from the stack/group. The colored arrows indicate the edit flow of
a command. A list of actions available for a command is as follows:
•
Copy – move a copy of the command over to the edit portion of the window
•
Replace – replace the original command with the edited version
•
Insert – move the command in another location in the command stack
•
Delete – remove the command from the stack
•
Save As – store a copy of the stack on the PC including blackboard items
•
CSV File Conv – create a file for printing that does not include blackboard items
Note: Under the Edit column on the right of the window provides common commands
as well as a stack closing command, Period of group. It is unnecessary to add this
command at the end of your command stack unless you wish to add a second
stack/group. Eliminating a Period of group command causes two separate groups
to merge in to a single stack/group.
Click on a command from the list on the left then choose an action to apply to that
command. Once the group is altered in any way, the OK button becomes active.
Click on OK to save your changes.
To download the barcode command stack, press the Download button at the lower
left corner of the Command Stack/Blackboard pop-up window.
Blackboard
The Blackboard settings are as follows:
•
Num of group – Total number of Blackboard displays
If no data is present, the number remains as ‘1’.
•
Num of unit – the total number of graphic
pages
in the group
•
Num of data – the total number of blackboard objects in the group
Example of blackboard data:
Num of group
001
first blackboard group
Num of unit
002
2 “pages” of blackboard items
Num of data
005
3 objects on one page and 2 objects on a second page