47) REGISTER C SET
LD/CD
Function:
Changes the current setting of Register C. (Miscellaneous)
Format:
Integer
R C
Explanation:
When power is turned ON, and SW 4 is set ON/DOWN, the Side
Repeat function of Register C is set to ON. If Function Switch 5 on
the rear panel of the player is ON (DOWN), the Load Start and
Power-On Start functions of Register C are also set to ON. If
Function Switch 6 is ON (DOWN), background color will be set to
Black. Baud Rates of 9600 and 2400 cannot be set with this
command. Note that some functions, such as Test Mode, may
suspend playback or disable further control.
Test Mode is for use
only by Authorized Service Centers, for evaluating player operations.
The functions listed below can be set. To set a function to ON,
give the value indicated by the integer. To set multiple functions
to ON, the integer values must be added up. All eight functions can
be specified in combination by using the decimal values from 0 to
255. The completion status is returned immediately.
NOTE:
When “All Repeat”, “Side Repeat”, “Chapter Repeat” or
“Track Repeat” is selected by the RCU, the “Side Repeat” function of
Register C goes to “ON” and when “Auto Return” is selected by the
RCU, the “Side Repeat” function of Register C goes to “OFF”.
Execution:
* Initial value 0
3 R C <C/R>
R <C/R>
* Side-Repeat, Load-Start to ON, background color BLUE
1 6 R C <C/R>
R <C/R>
* Background Color BLACK; Side-Repeat and Load-Start to OFF
3-42
TP 121 v. 1.0 • 1/96
CLD-V5000 Level III User’s Manual
Chapter Three • CLD-V5000 Level III
Integer
Function
1
0
1
Repeat
ON
OFF
2
Load-Start
ON
OFF
4
Power-on-Start
ON
OFF
8
(Not Used)
—
—
16
Background Color
BLACK
BLUE
32
TxD Terminator
<CR+LF>
<CR>
64
BAUD Rate
1200
4800
128
Test Mode
ON
OFF
Figure 3-U