![Pioneer CDJ-1000MK2 Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/pioneer/cdj-1000mk2/cdj-1000mk2_service-manual_327943072.webp)
CDJ-1000MK2
72
1
2
3
4
1
2
3
4
C
D
F
A
B
E
⁄
Mode for checking the load on the Jog dial
In this mode, the load (light/heavy) on the Jog dial while it is rotated is subjectively measured.
JOG Check Mode : ON
Measuring method
In this state, if you rotate the Jog dial rapidly either clockwise or counterclockwise, figures are displayed.
For example, if "16.14 0135" is displayed, it means as follows:
16.14: Highest speed (given that the normal [1x] speed is when it takes 1.8 sec for the Jog dial to rotate one full turn.)
0135: Time (msec) required for the Jog dial to decrease its speed from 3x speed to 1.5x speed
As to the time required for the Jog dial to decrease its speed, if the measurement is performed for several times
repeatedly, from the second measurement and afterward, the average of the current required time and the previous
required time is displayed. Thus, after several measurements, the result becomes closer to the mean.
Notes
• Perform the measurement of load on the Jog dial more than three times.
• The measurement result is displayed only when the Jog dial is rotated 7 times normal speed "07.00" or more.
Management value
Jog management value: 150
±
25 (msec)
Load adjustment method
Remove the screw fixing the adjust plate, then screw it into the hole corresponding to the value (-1, -2, -3, +1, or +2) for a
load to be added:
-1, -2, -3 : To decrease the load
+1, +2
: To increase the load
CALL
POWER SW
POWER ON
FWD+ REV
+
Rotation speed
Time (msec)
FL display
-1
-2
-3
+2
+1
0
To increase
the load
To decrease
the load
Adjust plate
JOG Check Mode : CANCEL