AVH-P3100DVD/XN/UC
104
1
2
3
4
1
2
3
4
C
D
F
A
B
E
TEST MODE
1: LD ON
2: ASMAX
3: Skew Adjustment
4: Error Rate
5: CRG Move Outer
6: Eject
Please Input Number
Skew Adjustment
Select “1: DVD Single Layer.”
Skew Adjustment
1: DVD Single Layer
5: Return
Please Input Number
There are two methods of making adjustment: a method of making adjustment through monitoring RF waves by the
oscilloscope (method 1) and a method of making adjustment through checking the numerical value of the RF level by
OSD (method 2).
Adjusting procedure is shown below, but regarding how to start the test mode and the operating procedure, please refer
to the clause on the service test mode.
Adjusting Procedure:
1. Install the pickup
(Refer to the removal of the pickup from the mecha unit.)
When handling the pickup, refer to the precautions on how to handle the PU listed below.
2. Method 1:
Connect the oscilloscope according to the AGND3 standards with reference to the connection diagram so that the RF
signals can be monitored.
Method 2:
The device does not need to be set. Proceed to the procedure 3.
3. Turn ON the power of the product.
4. Start the simplified FE test mode.
(Regarding how to start the test mode and the operating procedure, refer to the clause on the service test mode.)
5. Load the disc for adjustment (TDV582).
6. TEST MODE
Select “3: Skew Adjustment.”
Adjust the Skew using a driver while checking the RF value.
Refer to the following pages concerning the locations to make SKEW adjustment.
Method 1:
Slightly turn the skew adjusting screw A while checking the RF wave level by the oscilloscope and make
adjustment so the wave level would reach its maximum.
Next, slightly turn the skew adjusting screw B so the wave level would reach its maximum.
Slightly turn the skew adjusting screw A again so the wave level would reach its maximum.
(Make adjustment in the order of A->B->A and in the end complete adjustment by turning each screw
in the clockwise direction.)
Method 2:
Slightly turn the skew adjusting screw A while checking the value of the RF level through the OSD display so the wave
level would reach its maximum.
Next, slightly turn the skew adjusting screw B so the level would reach its maximum.
Slightly turn the skew adjusting screw A again so the level would reach its maximum.
(Make adjustment in the order of A->B->A and in the end complete adjustment by turning each screw in the
clockwise direction.)
Содержание AVH-P3150DVD
Страница 29: ...AVH P3100DVD XN UC 29 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 56: ...AVH P3100DVD XN UC 56 1 2 3 4 1 2 3 4 C D F A B E Side A COMPOSITE GNDV Fig 11 3 VIDEO signal check point ...
Страница 59: ...AVH P3100DVD XN UC 59 5 6 7 8 5 6 7 8 C D F A B E Side A DGND1 IC1501 50pin Fig 13 3 48 MHz check point ...
Страница 61: ...AVH P3100DVD XN UC 61 5 6 7 8 5 6 7 8 C D F A B E Side A SCLOCK SDATA D CP_ RESET D DGND2 ...
Страница 67: ...AVH P3100DVD XN UC 67 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 114: ...AVH P3100DVD XN UC 114 1 2 3 4 1 2 3 4 C D F A B E 9 1 PACKING ...
Страница 116: ...AVH P3100DVD XN UC 116 1 2 3 4 1 2 3 4 C D F A B E 9 2 EXTERIOR 1 A A A B ...
Страница 118: ...AVH P3100DVD XN UC 118 1 2 3 4 1 2 3 4 C D F A B E 9 3 EXTERIOR 2 A A E F 2 1 ...
Страница 122: ...AVH P3100DVD XN UC 122 1 2 3 4 1 2 3 4 C D F A B E A GEM1045 B GEM1038 C GEM1024 A C C A A C C C C C A A ...
Страница 123: ...AVH P3100DVD XN UC 123 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 127: ...AVH P3100DVD XN UC 127 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 145: ...AVH P3100DVD XN UC 145 5 6 7 8 5 6 7 8 C D F A B E ...