5
Safety Signs
Number 1
Spraying hazard. Disconnect power before servicing the
applicator
Part no. DCL-8003
Number 2
Read and understand the
operator’s manual before using or
working around the equipment.
Part no. DCL-8000
Number 3
Falling hazard. Do Not Step in this area.
Part no. DCL-8002
Number 4
Eye protection. Pressure Relief Valve.
Part no. DCL-8005
Operation for Non-GreenStar
Equipped Machines
On / Off Button
This button will turn the box on and off. Turning the unit off also
activates the automatic clean-out function. When the unit is first
turned on, the display will show either GS or SL briefly, then will
display STOP. The box can be shut off in any of the operating
modes. When you turn the unit off, you will notice that the
machine does not immediately turn off, instead CLN is shown in
the display. This is part of the automatic clean-out function. The
pumps will run a clean-out cycle for 30 seconds and then turn
off. There is no need to press the ON/OFF button again when
CLN is displayed. If the off button is accidentally pressed during
operation, you will have to wait for the applicator to go through
the clean-out cycle before it can be turned back on.