Troubleshooting
Symptom
Possible Cause
Squeeze Pump does not start
Fault in wiring
Squeeze Pump will not prime
Air leak in intake
Faulty wiring
Squeeze Pump runs but does not pump
product
Pump hose is broke
Gauge Pressure is ABOVE 30 psi
Plugged spray tip or filter
Line restriction
Brass Pop-off valve is stuck
Gauge Pressure is BELOW 20 psi
Tip Missing
Strainer bowl screen is plugged
Broken hose
Fault in wiring to injector pump
Plugged intake filters
Worn compressor
Compressor head need rebuild kit
Control displays MORE tons treated
than product used
Clog in injection line
Fault in wiring to injection pump
Bad injection pump
Faulty injection pump motor
Clog in breather tube
Build up in output line
Partially plugged spray tip
Leaking bottle acceptor assembly
Faulty injector pump motor
Partially clogged spray tip
Calibration off
Control displays LESS tons treated than
product used
Bad injection pump tubing
Bad 1/4” tubing
Fault in wiring
Leak in breather tube or bottle
Faulty injection pump motor
Calibration off
Control Display shows only
"
.
"
or
"
-
"
Hold “Ton Treated” button for 3
seconds to reset.
If problem is not corrected, send
control box in for repair.
C500 does not spray out the tip during
cleanout cycle
Plugged tip
Plugged inline filter
Buildup in 1/4" hose
Control shuts off without going through
cleanout cycle
Power connected to keyed source
Faulty wiring harness
Faulty control
C500 will not apply when control is in
normal operating mode
Faulty wiring harness
Faulty compressor or injector pump
wiring
Applicator does not apply when using
the end or row option
Wiring harness connection is reversed
Faulty wiring harness
Faulty injector pump wiring
Faulty control box
Blown fuse on harvester
No signal from machine
Machine's head is not in the
lowered position
Machine is not moving forward
Check for voltage at green wire
while harvester is operating.
Bubbles in tank during prime cycle.
Squeeze pump wiring is reversed.
Blue wire must be connected to
bottom lug.
Squeeze pump tubing is reversed.
Compressor will not build pressure
Plugged intake filters
Plugged pre-filter
Air leak in hose connections
Broken hose
Dirt in compressor
Faulty check valves
Blowing 15 amp in-line fuse
Faulty wiring, Faulty control box
Bad connection to battery
Air compressor filters plugged
Faulty air compressor
Call for Further Assistance
During Normal Business Hours
1-877-Pioneer (746-6337),
ext. 82526 or 82280
After Hours or Weekends
1-765-437-7211