4 - Octagonal
Junction Box
5” Power Canopy
Strain Relief
18ga. SJT Cord
Cross-Bar
Conduit and Fittings
(by others)
1/4-20 Stud
#8 Junction
Box Screws
IDS Clip
Tie-Off to structure
2” Non-Power Canopy
Aircraft Cable
Coupler
Coupler
12655 E. 42nd Ave. #50 Denver, CO 80239
Phone: 303.322.5570 Fax: 303.322.5568
www.pinnacle-ltg.com
T5/T5HO/T8/LED
Step 2:
Non Power Mount
Step 1:
Power at Ceiling
1. Layout mounting/ junction box locations. Begin row
with fixture label at first mounting point.
2. Install junction box onto T-Bar ceiling. Tie box off to
structure. Install conduit from building power
3. Thread 1/4-20 stud to crossbar for power. mounts.
Install crossbar to junction box.
4. Run SJT cord through canopy, make necessary power
connections, secure using strain relief.
5. Feed aircraft cable through coupler.
6. Secure canopy to crossbar bolts using aircraft cable
coupler.
1. Install IDS clips for non-power mounts. Tie off to structure.
2. Feed aircraft cable through coupler.
3. Secure canopy to IDS clip using aircraft cable coupler.
AC - to - Grid Mount
EDGE
EX33
EX44
© 2017 Pinnacle Architectural Lighting
EdgeEX33_44_Booklet_January 2017
3 of 25
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the
construction and operation of the product.
2. Minimum 90ºC supply conductors
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Fixtures must be mounted directly to structure.
5. The holding strength of AC cables cannot be guaranteed if the cables are damaged in any way.
Return to
Main Menu
AC cables with damage, bends, kinks, fraying, or knots must be discarded and replaced with new components. Never install a fixture where the AC cable is more than 5 degrees from perpen-
dicular to the fixture. Fixtures are never to be raised by the cables (instead, lift the fixture up and adjust the cable position). Overtightening of hardware on grippers can damage AC cables. Never
exert force down onto the top of the fixture once it is hanging by safety cables. Never cut safety cables prior to installation. The first zip tie on the SJT and AC cables below the ceiling/canopy
must be no closer than 12” from the ceiling/canopy
Содержание EDGE EX33
Страница 2: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO GRID MOUNT INSTALLATION...
Страница 4: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO JB MOUNT INSTALLATION...
Страница 6: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO ST MOUNT INSTALLATION...
Страница 8: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO FIXTURE INSTALLATION...
Страница 11: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO JB MOUNT INSTALLATION...
Страница 13: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO ST MOUNT INSTALLATION...
Страница 15: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO FIXTURE INSTALLATION...
Страница 18: ...EDGEEX33 EX44 T5 T5HO T8 LED SURFACE MOUNT INSTALLATION...
Страница 21: ...EDGEEX33 EX44 T5 T5HO T8 LED WALL MOUNT INSTALLATION...
Страница 24: ...EDGEEX33 EX44 LENS DETAIL...