background image

4 - Octagonal 
Junction Box
(by others)

Conduit and Fittings
(by others)

Pendant Crossbar (3/8 IP)

#8 Junction Box Screws
(by others)

5” Slip Canopy

3/8 IP Pendant Pipe

Set Screw

4 - Octagonal 
Junction Box
(by others)

Pendant Crossbar (3/8 IP)

#8 Junction Box Screws
(by others)

5” Slip Canopy

3/8 IP Pendant Pipe

Set Screw

12655 E. 42nd Ave. #50 Denver, CO 80239

Phone: 303.322.5570 Fax: 303.322.5568

www.pinnacle-ltg.com

PP - to - ST Mount

Step 2:

Non Power Mount

Step 1:

Power at Ceiling

1. Install 4-Octagonal Junction boxes to structure at all 
mounting locations.

(see spacing on page 2). 

Begin row with 

fixture label at first mounting point.
2. Install conduit from building power to J-Box.
3. Install crossbar to J-Box
4. Feed slip canopy over pendant and secure pendant to 
crossbar.
5. Feed power from J-Box through pendant and out leav-
ing 12” for fixture wiring.
6. Make all necessary wiring connections.

1. Attach 4-Octagonal Junction boxes to structure at all 
mounting locations.
2. Install crossbar to J-Box.
3. Slide slip canopy over pendant.
4. Rotate pendant onto crossbar.
5. Slide canopy up to ceiling level and secure with set 
screw.

EDGE

EX33

EX44

© 2017 Pinnacle Architectural Lighting

14 of 25

EdgeEX33_44_Booklet_January 2017

T5/T5HO/T8/LED

1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the 
construction and operation of the product.
2. Minimum 90ºC supply conductors
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Fixtures must be mounted directly to structure.
5. The holding strength of AC cables cannot be guaranteed if the cables are damaged in any way.

Return to

Main Menu

Содержание EDGE EX33

Страница 1: ...allation 6 7 T5 T5HO T8 LED AC to Fixture 8 10 T5 T5HO T8 LED PP to JB Mount Installation 11 12 T5 T5HO T8 LED PP to ST Mount Installation 13 14 T5 T5HO T8 LED PP to Fixture 15 17 T5 T5HO T8 LED Surfa...

Страница 2: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO GRID MOUNT INSTALLATION...

Страница 3: ...id Mount EDGEEX33 EX44 2017 Pinnacle Architectural Lighting EdgeEX33_44_Booklet_January 2017 3 of 25 1 This product must be installed in accordance with applicable installation and electrical codes by...

Страница 4: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO JB MOUNT INSTALLATION...

Страница 5: ...ctural Lighting EdgeEX33_44_Booklet_January 2017 T5 T5HO T8 LED 5 of 25 1 This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with...

Страница 6: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO ST MOUNT INSTALLATION...

Страница 7: ...ust be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product 2 Minimum 90 C supply conductors 3 All el...

Страница 8: ...EDGEEX33 EX44 T5 T5HO T8 LED AC TO FIXTURE INSTALLATION...

Страница 9: ...stalled in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product 2 Minimum 90 C supply conductors 3 All electrical...

Страница 10: ...n past hand tight to com plete joining and create ground Step 5 Joining Fixtures 1 Install end plates prior to lens louver installation 2 Place against end of fixture and secure using two 2 6 32 nuts...

Страница 11: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO JB MOUNT INSTALLATION...

Страница 12: ...Feed power from J Box through pendant and out leaving 12 for fixture wiring 6 Make all necessary wiring connections 1 Attach 4 Octagonal Junction boxes to structure at all mounting locations 2 Instal...

Страница 13: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO ST MOUNT INSTALLATION...

Страница 14: ...Feed power from J Box through pendant and out leav ing 12 for fixture wiring 6 Make all necessary wiring connections 1 Attach 4 Octagonal Junction boxes to structure at all mounting locations 2 Instal...

Страница 15: ...EDGEEX33 EX44 T5 T5HO T8 LED PP TO FIXTURE INSTALLATION...

Страница 16: ...individual one 1 mount at opposite end for every fixture after 2 Tighten down Nut to secure pendant pipe to fixture 3 If power side mount run power wires into housing through pen dant pipe Note Once...

Страница 17: ...ns louver installation 2 Place against end of fixture and secure using two 2 6 32 nuts Step 6 Finishing 1 Install End Trim after louver installation Two 2 per 4 section Three 3 per 8 section Four 4 pe...

Страница 18: ...EDGEEX33 EX44 T5 T5HO T8 LED SURFACE MOUNT INSTALLATION...

Страница 19: ...others EX33 width 2 7 8 EX44 width 4 7 16 Plug Hole Size 7 8 3 8 IP Reflector Lens Reflector Screws Through wire If MR16 Unit 2 1 4 91 1 2 2 1 4 2 1 4 2 1 4 43 1 2 48 Individual Spacing 96 8 8 8 First...

Страница 20: ...ast hand tight to com plete joining and create ground Step 3 Joining Fixtures 1 Install end plates prior to lens louver installation 2 Place against end of fixture and secure using two 2 6 32 nuts Ste...

Страница 21: ...EDGEEX33 EX44 T5 T5HO T8 LED WALL MOUNT INSTALLATION...

Страница 22: ...kit hardware 2 Slip adjacent fixture s mounting hardware through the keyhole slots on the end plates 3 Make wiring connections between fixtures and recess wires into one of the fixtures 4 Tighten join...

Страница 23: ...center of bracket 3 4 Center to center of bracket 7 4 Center to center of bracket 11 4 Center to center of bracket 24 36 48 96 144 16 28 40 88 136 Note Power typically on left side of fixture Wall Mou...

Страница 24: ...EDGEEX33 EX44 LENS DETAIL...

Страница 25: ...temporarily decreasing the width of the lens 1 Insert a rigid object approx 1 16 thick such as a quarter into the edge between the lens and the fixture approx 1 2 from the end of the lens 6 for regre...

Отзывы: