Kerosene Radiant Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

7

OPERATION

Fueling The Heater:

Kerosene

For optimal performance of this heater, it is 

strongly suggested that Kerosene be used. 

Kerosene has been refined to virtually eliminate 

contaminants, such as sulfur, which can cause 

a rotten egg odor during the operation of the 

heater. Using diesel fuel can cause excess soot 

production. Do not use Bio-Diesel as this fuel 

will damage your heater’s seals and filter.

 - CSA certified for use with K-1 kerosene, no. 1 & no. 

2 diesel, JP8/Jet A Fuel, no. 1 and no. 2 fuel oil.

- NEVER use fuel such as, benzene, alcohol, white 

glass, camp stove fuel, farm diesel, paint thinners, 

or other oil compounds in this heater. THESE ARE 

VOLATILE FUELS THAT CAN CAUSE A FIRE OR 

EXPLOSION.

- NEVER store Kerosene in the living space. 

Kerosene should be stored in a well ventilated 

area outside the living area.

 - NEVER store Kerosene in direct sunlight or near a 

source of heat.

 - NEVER use Kerosene that has been stored from 

one season to the next. Kerosene deteriorates 

over time. OLD Kerosene WILL NOT BURN 

PROPERLY IN THIS HEATER. 

NOTE: Kerosene should only be stored 

in a blue container that is clearly marked 

“Kerosene.” Never store Kerosene in a red 

container. Red is associated with gasoline.

Ventilation:

 - Risk of indoor air pollution and Carbon 

Monoxide Poisoning. Use heater only in well 

ventilated areas.

 - Refer to Safety Information on pages 2-3 for 

information about Carbon Monoxide Poisoning.

 - ALWAYS

 provide a fresh air opening in the heated 

space of at least 2,800 square centimeters  

(3 sq. ft) for each 100,00 Btu/Hr. (29 kW) of 

heater output. Provide a larger opening if more 

heaters are being used. 

Minimum Ventilation Opening Needed

80-OFR-O

125-OFR-O

2.4 ft.

2

3.75 ft.

2

2230 cm

2

3484 cm

2

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

NEVER REFUEL 

THIS HEATER 

WHILE IT IS HOT 

OR OPERATING. FIRE OR EXPLOSION 

COULD RESULT. 

DANGER

DANGER

NEVER FILL 

THE FUEL TANK 

INDOORS. AL-

WAYS FILL THE TANK OUTDOORS. BE 

SURE THAT THE HEATER IS ON LEVEL 

GROUND WHEN FUELING, AND NEVER 

OVERFILL THE TANK.

CAUTION

DO NOT USE 

GASOLINE OR 

CRANKCASE 

DRAININGS. 

WARNING

Содержание Remington REM-125-OFR-O

Страница 1: ...QUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvented portable heater that uses air Oxygen from within the area in which it is used Failure to provide...

Страница 2: ...ATER WHEN THE CHAMBER IS HOT WARNING WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as r...

Страница 3: ...The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction alte...

Страница 4: ...ption Gal Hr L Hr 0 63 2 38 0 85 3 22 Fuel Tank Capacity Gal L 4 15 14 14 53 00 Max Operating Hours 6 20 Volts AC Hz 120V 60Hz 120V 60Hz Amps 3 15 3 15 Heating Area ft 2 2000 3125 Specifications subje...

Страница 5: ...Attach the handle while still in the box for easier unpacking see Figures 1 and 2 Carry Handle 1 Black Screws 2 80 OFR O 1 Remove existing screws from shell ring on either side of heater see Figure 3...

Страница 6: ...ed see Figure 8 4 Attach Radiant Visors to the top and bottom rear of the Radiant Cone Assembly using extra screws included 5 Attach top safety guard using the two outer most extra screws on the top o...

Страница 7: ...ct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosen...

Страница 8: ...fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the power swi...

Страница 9: ...SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5 mm see Figure 12 FAN...

Страница 10: ...ozzle in clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a c...

Страница 11: ...te Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 11 125 OFR O WIRING DIAGRAMS AC 120V 60Hz AC 250V 3 15A ELECT...

Страница 12: ...lug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transformer w...

Страница 13: ...s Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 13 EXPLODED VIEW 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Страница 14: ...0650 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit...

Страница 15: ...erosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 4...

Страница 16: ...ump 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower M...

Страница 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Страница 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Страница 19: ...FICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MODIFICACI N O REPARACI N Este es un calentador port til sin ventilaci n que utiliza aire ox geno del rea en la que se usa Si no se sumini...

Страница 20: ...ENCIA NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de construcci n papel o cart n...

Страница 21: ...Los productos descritos en este manual son calentadores de aire forzado de fuego directo de queroseno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal...

Страница 22: ...z 120 V 60 Hz Amperaje 3 15 3 15 rea de calefacci n pies2 m 2 2000 185 3125 290 Las especificaciones pueden cambiar sin previo aviso CARACTER STICAS PROTECCI N DE SEGURIDAD PLACA DE CALOR ANILLO DE LA...

Страница 23: ...cuando a n est en la caja para facilitar el desempaque vea las Figuras 1 y 2 Asa 1 Tornillos negros 2 80 OFR O 1 Retire los tornillos existentes del anillo de la coraza en ambos lados del calentador...

Страница 24: ...8 4 Sujete los visores radiantes a la parte trasera superior e inferior del conjunto del cono radiante con los tornillos adicionales incluidos 5 Sujete la protecci n de seguridad superior con los dos...

Страница 25: ...e queroseno que se haya estado almacenado de una temporada a la siguiente El queroseno se deteriora con el tiempo EL queroseno VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno deb...

Страница 26: ...este fusible y reempl celo si es necesario Tambi n revise la fuente de alimentaci n el ctrica para asegurarse que se est suministrando el voltaje correcto al calentador 1 Complete los pasos 1 a 3 desc...

Страница 27: ...trodos de la buj a despu s de cada 600 horas de funcionamiento o reempl cela seg n sea necesario Despu s de extraer la buj a limpie las terminales con una cepillo de alambre Reajuste la separaci n de...

Страница 28: ...jen las part culas vea las Figuras 14a y 14b FOTOC LULA La fotoc lula debe limpiarse al menos una vez por cada temporada de calefacci n o m s seg n las condiciones en que est Utilice un hisopo de algo...

Страница 29: ...A BUJ A ENCENDEDOR MOTOR DE ENFRIAMIENTO PLACA DE CIRCUITOS IMPRESOS LUZ DE FUNCIONAMIENTO LUZ DE REVISI N DE ERROR PCI DE CONTROL INTERRUPTOR ANTIVUELCO INTERRUPTOR DE LIMITE DE TEMPERATURA FOTOC LUL...

Страница 30: ...del tanque con queroseno o di sel nuevo y limpio 6 Inspeccione todas las conexiones el ctricas Consulte los Diagramas el ctricos en la p gina 11 7 Reconecte los cables del transformador a la buj a 8 R...

Страница 31: ...l calentador radiante de queroseno NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS EST ENCENDIDO O MIENTRAS EST CONECTADO A UNA FUENTE DE ALIMENTACI N 13 VISTA DETALLADA 25 23 24 9 21 22 20 19 26 10 7 2...

Страница 32: ...ctrica 75 027 0650 9 Encendedor 75 025 0120 10 Conjunto de la placa de circuitos impresos principal 75 025 0400 11 Interruptor antivuelco 75 051 0200 12 Conjunto del motor de enfriamiento 75 047 0250...

Страница 33: ...ntador radiante de queroseno NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS EST ENCENDIDO O MIENTRAS EST CONECTADO A UNA FUENTE DE ALIMENTACI N 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22...

Страница 34: ...e 72 027 0100 11 Placa de circuitos impresos principal y fusible 72 025 0450 12 Interruptor antivuelco 75 051 0200 13 Cable el ctrico 72 032 0150 14 Interruptor de encendido 72 012 0120 15 Cubierta po...

Страница 35: ...echnologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reemplaza a todas...

Страница 36: ...strial Blvd 101 Sauk Rapids MN 56379 USA Llamada sin costo 866 676 1989 Fax 320 251 2922 Sitio web www remingtonheater com Correo electr nico info pinnacleclimate com 2018 Pinnacle Climate Technologie...

Отзывы: