Hunter-Pro Series Captain 8 - Installation Guide
66
[NEXT] Output type
The event that triggers it
X9
Panic
Alarm in a “Panic” zone, or pressing the panic key combination
[*]+[#].
X10
Silent Panic
Alarm in a “Silent Panic” zone
X11
Hold-Up (Duress) Alarm in a “Hold-Up (Duress)” zone, or entering the
“Duress” code
X12
Medical
Alarm in a “Medical” zone
X13
Alarms - All Types Any alarm
X14
Audio Control
Triggering an audio module: MIC-200 or VU-20N/U
X15
Zone Open
Opening a zone (regardless of the panel status)
X16
Zone Bypassed
Zone is bypassed by a user
X17
Smoke Detector
Power
Resetting smoke/fire detectors
X18
Tamper
Opening a tamper switch (connected via TMPR1/TMPR2
terminals)
X19
Zone tamper/fail
Opening a zone tamper, or a zone failure
X20
Buzzer
Activating the "Buzzer" output type
X21
Armed
Arming the panel to any mode
X22
Installer Program
Entering the Installer code
X23
General Fault
AC, Low battery or Phone line faults occur
X24
Mains Fault
AC fault occurs
X25
Low Battery
Low battery fault occurs
X26
Phone Fault
Phone line fault occurs
X27
GSM Fault
GSM fault occurs
X28
Comm. Fault
Communication fault occurs
X29
Not In Use
-
X30
Door Code
Entering the Door code
X31
Wireless Remote
Pressing the [*] button in a remote control
1
X32
Test
Performing a test
X33
Not In Use
-
X34
Not In Use
-
X35
Remote Control
Activating an output by telephone
Not in use in Captain 8
X36
Not In Use
-
X37
Station ACK
This output type is triggered upon receiving an ACK from the
Monitoring Station
The assigned output is triggered for 20 sec. (not programmable)
X38
Chime follower
Opening a “Chime” zone. This can be used for a second
indication, e.g., speaker, another buzzer, etc.
[BACK] net4pro Comm
FLT
The net4pro module failing to communicate with the Monitoring
station (including retries). The allocated output will be triggered
for 5 sec. (not programmable)
1
I.e., triggering an output.