Hunter-Pro Series Captain 8 - Installation Guide
18
In “Scan Open Zones” displaying mode
Following are examples for the wireless receiver faults:
Display
Fault
I/O-WN communication fault
I/O-WN open tamper
Tamper open, zone #14
Low Battery, zone #19
No supervision signal, zone #35
The I/O-WN is not enabled in the “System Installation” menu (see
section 4.2.2, on page 45).
1.5.11.
EXP-PRO UNIV: local 8 zone expander
To use the EXP-PRO UNIV:
1.
Install the module inside the control panel’s box, above the PCB,
using the 2 supplied screws.
2.
Connect the supplied flat cable between the EXP-PRO UNIV
and PCB’s “Expansion Card” socket.
3.
To configure the EXP-PRO UNIV, refer to section 4.2.
Make sure JP2 jumper is placed on pins 1, 2.
Diagram 13.
Connecting the EXP-PRO UNIV
2 J U L 0 7 1 3 : 1 0
W i r e l e s s U n i t
1 J U L 0 7 0 3 : 0 0
W / L U n i t T a m p e r
5 J U N 0 7 1 4 : 2 0
F L : Z o n e 1 4
5 J U N 0 7 1 4 : 2 5
L B : Z o n e 1 9
7 O C T 0 7 1 6 : 3 2
S V : Z o n e 3 5
W / L R e c v r . f a i l
E N T E R / N E X T / E N D
Z16
Z15
Z14
Z13
GND (-)
12V (+)
1
JP2
JP3
Z9
Z10
Z11
Z12
GND (-)
12V (+)
Flat
cable
Zone inputs
Jumper
2 3
The Control panel
EXP
-
PRO UNIV
EXPANSION CARD
SERIAL
KEYPAD
TRANSMITTER
JP1
JP2
JP4
J
P
3