System Options
PIMA Electronic Systems
21
Chap. 9
System Options
The
System Options menu includes the settings of the users and the peripherals, and the alarm
system’s information.
The
System Options are as follows:
1)
Override Faults: see below.
2)
Zone Information: zone names, location, and status: see below.
3)
Armed Partitions: see next page.
4)
Time and Date: see page 22.
5)
Chime Zones: see page 22.
6)
Auto Arming: see page 23.
7)
Reset Smoke Detector: see page 23.
8)
Technician Permit: see page 24.
9)
System Information: see page 24.
9.1
Override Faults
User Menu
System Options
Override Faults
As with open zones, you cannot arm the
alarm system if a fault exists, and it must be fixed.
Only when there is no other option it can be overridden
10
. Overriding is valid for one arming
session and needs to be repeated every time you want to arm, as long as the fault exists.
Faults can breach the security of your alarm system and may also indicate
on burglary setup. Use the fault overriding option only when there is no
other option, fix the fault immediately or call for service technician.
To override a fault before or while you arm the alarm system, do as follows:
1.
Enter the
Master code.
2.
Scroll to
System Options and press .
3.
Press
Override Faults - the current faults are displayed.
4.
Press to select the displayed faults.
5.
Press to exit. You can now arm the alarm system.
9.2
Zone Information
User Menu
System Options
Zone Information
View information about the zones (detectors) and their status - open or closed, alarming, and
more, detailed below. If partitions are in use (see the
Glossary, on page 29), only those
allocated with both the keypad and the user will be displayed.
Press and hold the key to exit. Press * or # to scroll between zones.
1)
Name & Location: zone name and location. This information is set by the technician.
2)
Zone Status: the status of each defined zone is represented by letters, listed in the
table bellow.
10
If a fault cannot be overridden, call a service technician.
Содержание CLW532
Страница 1: ...FORCE Advanced Intruder Alarm System User Guide Including the Lite version Version 1 2 X...
Страница 35: ......