Partitioning
PIMA Electronic Systems
29
Appendix B
Glossary
Arm Away
When arming in Away mode all the detectors are armed and will set off the alarm if any
movement (or whatever the detector is design to detect) is detected.
When entering a user code, the exit delay that allows you to leave the premises without
triggering a detector, starts. When the delay time elapses, all the zones are armed.
The
FORCE
can be armed only if the message “Ready to Arm” is displayed and the green
LED illuminates.
FORCE
is ready to armed, when there are no
Open Zones (detectors) or Faults.
A zone is “Open” when it is in detection or alarm modes. To close (reinstate) a zone, you need
to remove the cause for the detection - moving objects, open protected door, etc.
FORCE
cannot
be armed if there are open zones.
Existing faults also prevent arming, but some faults can be overridden in a special menu
13
. To
override faults before arming the
FORCE
, go to
User Menu
System Options
Overriding
Faults, select the fault and exit the menu. Overriding faults is a one-time operation and needs
to be repeated every time you want to arm the alarm system. Call service if the fault cannot
be fixed.
Arm Home
When arming
FORCE
to a Home mode, only some detectors (zones) are armed, while some are
not. This mode is used for arming defined areas like floors, perimeter detectors, shops, etc. It
allows you to be in areas that are not armed, while entering Home armed zones will trigger the
alarm. The technician can set up to four Home modes (areas).
Backup battery
The backup battery enables the alarm system to continually safeguard the premises for a
limited time, at AC power fault. Cutting power cords is common among burglars, and the
backup battery ensures that the alarm system will continue to protect the premises. When a
“Low Battery” message appears with no previous power fault, replace the battery.
Chime and chime zones
Chime is a feature by which the alarm system supervises doors and windows, and sounds a
series of beeps any time one of these is opened. The chime is active only when the alarm
system is disarmed. The chime feature is useful with toddlers and in shops, but also when door
or window are away from you.
The technician, together with you, define the chime zones that will trigger the keypad buzzer
when opened.
Duress code
A code used when a user is forced to disarm the alarm system. When this code is entered, the
alarm system is disarmed, but also sends a silent distress signal to the CMS (where relevant)
and the contacts, without giving any indication to that.
Tip: to remember the code easily, use the Master (or user) code, but switch around the last two
digits. For example, if the original code is 280961, set the Duress code to 280916
Entry and exit delays
After arming or disarming the alarm system, the exit and entry delays give you the needed time
to exit or enter the premises without triggering the alarm, by crossing only delayed zone (set by
the technician). These zones will not set off the alarm as long as the delay timer is in progress
(but will if are still open when the delay elapses).
13
The technician sets which faults you can override and which you cannot.