PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
56
No. Action
OK
NOT OK Notes
8
Check the output circuitry of the pro-
grammable safety and control system
Have OSSDs been incorporated as required
for the desired safety category?
Are the switching elements that are connec-
ted to the OSSDs (valves, contactors, etc.)
monitored with feedback loops?
Does the wiring of the OSSDs match the cir-
cuit diagram?
9
Check guard function for protected field
of the safety light grid:
Violate the protected field at various points:
The hazardous movement must be shut
down.
10
Switch off safety light grid
Is the hazardous movement stopped imme-
diately when you switch off?
EC declaration of conformity
This product/these products meet the requirements of the directive 2006/42/EC for ma-
chinery of the European Parliament and of the Council. The complete EC Declaration of
Conformity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost-
fildern, Germany