PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
46
Mechanical data
632063
632064
632065
Dimensions
Height
604 mm
754 mm
904 mm
Width
35 mm
35 mm
35 mm
Depth
40 mm
40 mm
40 mm
Weight
1.820 g
2.225 g
2.630 g
Where standards are undated, the 2015-12 latest editions shall apply.
Technical details Order no. 632066-632068
General
632066
632067
632068
Approvals
CE, TÜV
CE, TÜV
CE, TÜV
ESPE type
4
4
4
Sensor's mode of opera-
tion
Infrared
Infrared
Infrared
Height of protected field
1.050 mm
1.200 mm
1.350 mm
Resolution
Operating range
0,2 - 18 m
0,2 - 18 m
0,2 - 18 m
Detection capability
30 mm
30 mm
30 mm
Electrical data
632066
632067
632068
Supply voltage
Voltage
24 V
24 V
24 V
Kind
DC
DC
DC
Voltage tolerance
-25 %/+20 %
-25 %/+20 %
-25 %/+20 %
Residual ripple DC
5 %
5 %
5 %
Max. power consumption
receiver
12 W
12 W
12 W
Max. power consumption
transmitter
7,2 W
7,2 W
7,2 W
Max. inductive load per
output
1 H
1 H
1 H
Optical data
632066
632067
632068
Opening angle
-2,5 - 2,5 deg
-2,5 - 2,5 deg
-2,5 - 2,5 deg
Used wavelength range
850 nm
850 nm
850 nm
Inputs
632066
632067
632068
Max. overall line capacit-
ance Clmax
40 nF
40 nF
40 nF
Semiconductor outputs 632066
632067
632068
OSSD safety outputs
2
2
2
Switching current per out-
put
100 mA
100 mA
100 mA
Times
632066
632067
632068
Test pulse duration, safety
outputs
300 µs
300 µs
300 µs
Supply interruption before
de-energisation
600 µs
600 µs
600 µs