PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
41
[4] Optical centre axis
[5] Cable-side beam pair for beam synchronisation
[6] Wiring-side beam pair for beam synchronisation
[7] Eye shield
[8] Dead zone 70.3 mm
[9] Protected field perimeter markings
Schematic representation of the relationship between the safety light grid
dimensions and the effective protected field height
[1]
[2]
[3]
[4]
[5]
[6]
[1]
Fig.: Relationship between the effective protected field height and the safety light grid dimensions
(schematic representation)
Legende
[1] Resolution
[2] Last light beams on the connection and wiring sides
[3] Protected field height
[4] Effective protected field height
[5] Transmitter
[6] Receiver